Creatinine and urea biosensors based on a novel ammonium ion-selective copper-polyaniline nano-composite.

作者: M. Zhybak , V. Beni , M.Y. Vagin , E. Dempsey , A.P.F. Turner

DOI: 10.1016/J.BIOS.2015.10.009

关键词:

摘要: … Novel amperometric creatinine and urea biosensors based on a new PANi-Nafion-Cu composite and immobilised hydrolase enzymes (CDI and urease) have been developed and …

参考文章(52)
Alexey P Soldatkin, Jean Montoriol, William Sant, Claude Martelet, Nicole Jaffrezic-Renault, Creatinine sensitive biosensor based on ISFETs and creatinine deiminase immobilised in BSA membrane. Talanta. ,vol. 58, pp. 351- 357 ,(2002) , 10.1016/S0039-9140(02)00283-7
G.F. Khan, Wolfgang Wernet, A highly sensitive amperometric creatinine sensor Analytica Chimica Acta. ,vol. 351, pp. 151- 158 ,(1997) , 10.1016/S0003-2670(97)00362-0
Claudia Eggenstein, Michael Borchardt, Christoph Diekmann, Bernd Gründig, Christa Dumschat, Karl Cammann, Meinhard Knoll, Friedrich Spener, A disposable biosensor for urea determination in blood based on an ammonium-sensitive transducer Biosensors and Bioelectronics. ,vol. 14, pp. 33- 41 ,(1999) , 10.1016/S0956-5663(98)00103-1
Umesh Lad, Santosh Khokhar, Girish M. Kale, Electrochemical Creatinine Biosensors Analytical Chemistry. ,vol. 80, pp. 7910- 7917 ,(2008) , 10.1021/AC801500T
Gunjan Dhawan, Gajjala Sumana, B.D. Malhotra, Recent developments in urea biosensors Biochemical Engineering Journal. ,vol. 44, pp. 42- 52 ,(2009) , 10.1016/J.BEJ.2008.07.004
Andrea Pizzariello, Miroslav Stredanský, Silvia Stredanská, Stainslav Miertuš, Urea biosensor based on amperometric pH-sensing with hematein as a pH-sensitive redox mediator Talanta. ,vol. 54, pp. 763- 772 ,(2001) , 10.1016/S0039-9140(01)00331-9
J. Muñoz, C. Jimenez, A. Bratov, J. Bartroli, S. Alegret, C. Dominguez, Photosensitive polyurethanes applied to the development of CHEMFET and ENFET devices for biomedical sensing Biosensors and Bioelectronics. ,vol. 12, pp. 577- 585 ,(1997) , 10.1016/S0956-5663(96)00081-4
Yung-Chien Luo, Jing-Shan Do, Urea biosensor based on PANi(urease)-Nafion/Au composite electrode. Biosensors and Bioelectronics. ,vol. 20, pp. 15- 23 ,(2004) , 10.1016/J.BIOS.2003.11.028
Isao Taniguchi, Shigeyuki Miyamoto, Shimbu Tomimura, Fred M. Hawkridge, Mediated electron transfer of lactate oxidase and sarcosine oxidase with octacyanotungstate(iv) and octacyanomolybdate(iv) Journal of Electroanalytical Chemistry and Interfacial Electrochemistry. ,vol. 240, pp. 333- 339 ,(1988) , 10.1016/0022-0728(88)80335-8
Samuel B. Adeloju, Shannon J. Shaw, Gordon G. Wallace, Polypyrrole-based amperometric flow injection biosensor for urea Analytica Chimica Acta. ,vol. 323, pp. 107- 113 ,(1996) , 10.1016/0003-2670(95)00562-5