In vitro wear testing of a contemporary design of reverse shoulder prosthesis.

作者: S.L. Smith , B.L. Li , A. Buniya , S. Ho Lin , S.C. Scholes

DOI: 10.1016/J.JBIOMECH.2015.07.022

关键词:

摘要: … HoLin a SCScholes a G.Johnson a TJJoyce a … The lubricant employed was 50% newborn calf serum (Sigma-Aldrich n4637) giving an average protein content of 26 g/l. Gravimetric …

参考文章(30)
Bhairav Patel, Gregory Favaro, Fawad Inam, Michael J Reece, Arash Angadji, William Bonfield, Jie Huang, Mohan Edirisinghe, None, Cobalt-based orthopaedic alloys: Relationship between forming route, microstructure and tribological performance Materials Science and Engineering: C. ,vol. 32, pp. 1222- 1229 ,(2012) , 10.1016/J.MSEC.2012.03.012
Denis Nam, Christopher K. Kepler, Shane J. Nho, Edward V. Craig, Russell F. Warren, Timothy M. Wright, Observations on retrieved humeral polyethylene components from reverse total shoulder arthroplasty Journal of Shoulder and Elbow Surgery. ,vol. 19, pp. 1003- 1012 ,(2010) , 10.1016/J.JSE.2010.05.014
Judd S. Day, Daniel W. MacDonald, Madeline Olsen, Charles Getz, Gerald R. Williams, Steven M. Kurtz, Polyethylene wear in retrieved reverse total shoulder components Journal of Shoulder and Elbow Surgery. ,vol. 21, pp. 667- 674 ,(2012) , 10.1016/J.JSE.2011.03.012
Zachary M. Vaupel, Kevin C. Baker, Michael D. Kurdziel, J. Michael Wiater, Wear simulation of reverse total shoulder arthroplasty systems: effect of glenosphere design Journal of Shoulder and Elbow Surgery. ,vol. 21, pp. 1422- 1429 ,(2012) , 10.1016/J.JSE.2011.10.024
Victoria D Good, Ian C Clarke, G Allen Gustafson, Brandon Downs, Lucas Anissian, Kim Sorensen, Wear of ultra-high molecular weight polyethylene and polytetrafluoroethylene in a hip simulator: a dose-response study of protein concentration. Acta Orthopaedica Scandinavica. ,vol. 71, pp. 365- 369 ,(2000) , 10.1080/000164700317393358
R. W. Nyffeler, C. M. L. Werner, B. R. Simmen, C. Gerber, Analysis of a retrieved Delta III total shoulder prosthesis Journal of Bone and Joint Surgery-british Volume. ,vol. 86, pp. 1187- 1191 ,(2004) , 10.1302/0301-620X.86B8.15228
DAVID D. DEAN, CHERYL R. BLANCHARD, MICHAEL A. MILLER, CHARLES A. ROCKWOOD, MICHAEL A. WIRTH, C. MAULI AGRAWAL, JAY D. MABREY, Isolation and Characterization of Polyethylene Wear Debris Associated with Osteolysis Following Total Shoulder Arthroplasty Journal of Bone and Joint Surgery, American Volume. ,vol. 81, pp. 29- 37 ,(1999) , 10.2106/00004623-199901000-00005
S L Smith, A Unsworth, A comparison between gravimetric and volumetric techniques of wear measurement of UHMWPE acetabular cups against zirconia and cobalt-chromium-molybdenum femoral heads in a hip simulator Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine. ,vol. 213, pp. 475- 483 ,(1999) , 10.1243/0954411991535086
T J Joyce, D J Langton, S S Jameson, A V F Nargol, Tribological analysis of failed resurfacing hip prostheses and comparison with clinical data Proceedings of the Institution of Mechanical Engineers, Part J, Journal of Engineering Tribology. ,vol. 223, pp. 317- 323 ,(2009) , 10.1243/13506501JET484