Cementless total hip replacement: a prospective clinical study of the early functional and radiological outcomes of three different hip stems

作者: Philipp Bergschmidt , Rainer Bader , Susanne Finze , Alexander Gankovych , Guenther Kundt

DOI: 10.1007/S00402-009-0907-8

关键词:

摘要: Optimal fixation of cementless total hip stems is essential for long-term survival rates. The purpose this prospective study was to evaluate the early clinical and radiological outcomes two new with metaphyseal (Symax®) predominantly diaphyseal (Hipstar®) anchoring principles in comparison well-established straight Zweymueller (SL-Plus®) stem. Clinical evaluations 74 patients were undertaken preoperatively as well at 6 12 months postoperatively using Harris Hip Score (HHS) Western Ontario McMaster Universities-Score. During follow-up no stem had be revised. mean preoperative HHS three groups amounted 54.6 ± 15.7 points. At SL-Plus group (n = 22) 88.3 ± 10.5 points, Hipstar (n = 25) 83.3 ± 15.0 Symax (n = 27) 83.6 ± 15.1. Due stress shielding revealed radiolucent lines proximal Gruen zones about 60%, whereas showed significantly more (87%). However, subsequent studies must carried out order clarify if progression may influence result implant longevity.

参考文章(26)
EDUARDO GARCIA-CIMBRELO, ANA CRUZ-PARDOS, ROSARIO MADERO, MIGUEL ORTEGA-ANDREU, Total hip arthroplasty with use of the cementless Zweymüller Alloclassic system. A ten to thirteen-year follow-up study. Journal of Bone and Joint Surgery, American Volume. ,vol. 85, pp. 296- 303 ,(2003) , 10.2106/00004623-200302000-00017
F. Traulsen, J. Hassenpflug, H.-J. Hahne, Langzeitergebnisse zementfreier Hüftvollprothesen (Zweymüller) Zeitschrift Fur Orthopadie Und Ihre Grenzgebiete. ,vol. 139, pp. 206- 211 ,(2001) , 10.1055/S-2001-16322
J. Kircher, P. Bergschmidt, R. Bader, D. Kluess, E. Besser-Mahuzir, A. Leder, W. Mittelmeier, Die Bedeutung der Gleitpaarung beim jüngeren Endoprothesenpatienten Orthopade. ,vol. 36, pp. 337- 346 ,(2007) , 10.1007/S00132-007-1069-4
WILLIAM D. BUGBEE, WILLIAM J. CULPEPPER, C. ANDERSON ENGH, CHARLES A. ENGH, Long-term clinical consequences of stress-shielding after total hip arthroplasty without cement Journal of Bone and Joint Surgery, American Volume. ,vol. 79, pp. 1007- 1012 ,(1997) , 10.2106/00004623-199707000-00006
M. Schramm, F. Keck, D. Hohmann, R. P. Pitto, Total hip arthroplasty using an uncemented femoral component with taper design: outcome at 10-year follow-up Archives of Orthopaedic and Trauma Surgery. ,vol. 120, pp. 407- 412 ,(2000) , 10.1007/PL00013771
L. Jani, G. Scheller, R. Siebold, U. Schreiner, Langzeitergebnisse mit dem zementfreien CLS-Schaft von Spotorno Orthopade. ,vol. 30, pp. 317- 322 ,(2001) , 10.1007/S001320050614
Ohannes A. Nercessian, W.Howard Wu, Hasmik Sarkissian, Clinical and radiographic results of cementless AML total hip arthroplasty in young patients Journal of Arthroplasty. ,vol. 16, pp. 312- 316 ,(2001) , 10.1054/ARTH.2001.21503
B. C. H. van der Wal, B. J. de Kramer, B. Grimm, W. Vencken, I. C. Heyligers, A. J. Tonino, Femoral fit in ABG-II hip stems, influence on clinical outcome and bone remodeling: a radiographic study. Archives of Orthopaedic and Trauma Surgery. ,vol. 128, pp. 1065- 1072 ,(2008) , 10.1007/S00402-007-0537-Y
A Schuh, W Uter, U Holzwarth, W Kachler, J Göske, B Raab, T Knetsch, Residual particle free rough surfaces after rough blasting with steel grit in total hip arthroplasty Biomedizinische Technik. ,vol. 50, pp. 404- 407 ,(2005) , 10.1515/BMT.2005.056