Efficiency Calculations for a Magnetic Refrigerator Operating between 2 K and 10 K

作者: B. P. M. Helvensteijn , A. Kashani , P. Kittel

DOI: 10.1007/978-1-4613-0373-2_166

关键词:

摘要: An adiabatic demagnetization refrigerator (ADR) operating between 2 K and 10 has been built tested. The refrigerant in the ADR is Gadolinium Gallium Garnet (GGG). Absorption of heat at rejection this fully static made possible by incorporation switches. physical layout experimental results are presented a parallel paper, whereas current paper presents computational point view. performance as-built assessed taking into account dimensional features components, thermal characteristics components (heat capacity, latent heat, resistance), GGG entropy diagram loss mechanisms as they occur during refrigeration cycle (eddy heating, temperature gradients). summarized terms efficiency.

参考文章(6)
Gregory R. Gallagher, Analysis of a magnetically active regenerator Massachusetts Institute of Technology. ,(1986)
R. A. Fisher, G. E. Brodale, E. W. Hornung, W. F. Giauque, Magnetothermodynamics of gadolinium gallium garnet. I. Heat capacity, entropy, magnetic moment from 0.5 to 4.2 °K, with fields to 90 kG along the [100] axis Journal of Chemical Physics. ,vol. 59, pp. 4041- 4049 ,(1973) , 10.1063/1.1680677
Ronald D. Parks, O. V. Lounasmaa, Experimental Principles and Methods Below 1K ,(1974)
P. M. Ben Helvensteijn, Ali Kashani, Frank J. McCormack, Methods for Improving the Transfer of Heat across the Copper and Gadolinium Gallium Garnet Interface Advances in cryogenic engineering. ,vol. 39, pp. 1303- 1308 ,(1994) , 10.1007/978-1-4615-2522-6_160
A. Kashani, B. P. M. Helvensteijn, F. J. McCormack, A. L. Spivak, P. Kittel, Development of a Magnetic Refrigerator Operating between 2 K and 10 K Springer, Boston, MA. pp. 637- 646 ,(1995) , 10.1007/978-1-4757-9888-3_63
Zdeněk Kopal, Numerical analysis ,(1955)