Overdentures stabilised by two IMZ implants in the lower jaw--a 5-8 year retrospective study.

作者: Raghoebar Gm , Meijer Hj , van Oort Rp , Batenburg Rh , Stegenga B

DOI:

关键词:

摘要: Clinical and radiographical parameters were assessed in forty patients with overdentures stabilised by two IMZ implants connected a bar the lower jaw 5-8 years retrospective study. Results indicated that most had healthy peri-implant tissues, mean pocket probing depth was 3.1 mm median periotest value -4. Three removed after healing period replaced three new implants. One implant lost six years. mobile on palpation. None of showed objective signs dysaesthesia lip or chin. The bone level remained stable one year service. overall success rate 94% (Albrektsson et al.) it is therefore concluded implants, jaw, provide base for long-term support mandibular overdenture.

参考文章(16)
J Olivé, C Aparicio, Periotest method as a measure of osseointegrated oral implant stability. International Journal of Oral & Maxillofacial Implants. ,vol. 5, pp. 390- 400 ,(1990)
Hawker Pb, Ellies Lg, The prevalence of altered sensation associated with implant surgery. International Journal of Oral & Maxillofacial Implants. ,vol. 8, pp. 674- ,(1993)
H Spiekermann, E J Richter, V K Jansen, A 10-year follow-up study of IMZ and TPS implants in the edentulous mandible using bar-retained overdentures. International Journal of Oral & Maxillofacial Implants. ,vol. 10, pp. 231- 243 ,(1995)
G.J. van Beek, P.A.M. Versteegh, J.P. Ottervanger, A.P. Slagter, Clinical evaluation of mandibular overdentures supported by multiple-bar fabrication: a follow-up study of two implant systems International Journal of Oral & Maxillofacial Implants. ,vol. 10, pp. 595- 603 ,(1995)
Tomas Albrektsson, Evert Dahl, Lars Enbom, Sigfrid Engevall, Bo Engquist, Anders R. Eriksson, Günther Feldmann, Nils Freiberg, Per-Olof Glantz, Olof Kjellman, Lars Kristersson, Sven Kvint, Per-Åke Köndell, Jan Palmquist, Lars Werndahl, Per Åstrand, Osseointegrated Oral Implants Journal of Periodontology. ,vol. 59, pp. 287- 296 ,(1988) , 10.1902/JOP.1988.59.5.287
D. Van Steenberghe, M. Quirynen, Reproducibility and Detection Threshold of Peri-Implant Diagnostics Advances in Dental Research. ,vol. 7, pp. 191- 195 ,(1993) , 10.1177/08959374930070021001
Tomas Albrektsson, Lars Sennerby, State of the art in oral implants Journal of Clinical Periodontology. ,vol. 18, pp. 474- 481 ,(1991) , 10.1111/J.1600-051X.1991.TB02319.X
Marinus A.J. van Waas, The influence of clinical variables on patients' satisfaction with complete dentures Journal of Prosthetic Dentistry. ,vol. 63, pp. 307- 310 ,(1990) , 10.1016/0022-3913(90)90202-N
M. Quirynen, I. Naert, D. Van Steenberghe, Fixture design and overload influence marginal bone loss and fixture success in the Brånemark system. Clinical Oral Implants Research. ,vol. 3, pp. 104- 111 ,(1992) , 10.1034/J.1600-0501.1992.030302.X
J.I. Cawood, R.A. Howell, A classification of the edentulous jaws. International Journal of Oral and Maxillofacial Surgery. ,vol. 17, pp. 232- 236 ,(1988) , 10.1016/S0901-5027(88)80047-X