Study of impacts on operation of island and frequency based auto load shedding to improve service reliability using CYME PSAF

作者: Md Shafiullah , Hamidur Rahman , Md Quamrul Ahsan

DOI: 10.1109/ICECE.2012.6471617

关键词:

摘要: Formation of island may be inadvertent which is due to system fault or intentional for a purpose maintenance. Generally fall frequency lead by abnormal condition power and sometimes blackout an integrated occurred extreme abnormality. Though traditionally, interconnection standards avoid islanding operation but in case emergency islands can support local supplies critical important loads improve the service reliability. This paper presents different studies impact on as well develops based auto load shedding scheme addition generation loss island. The has been applied seven bus test validate effectiveness developed various conditions have simulated.

参考文章(9)
H. Zeineldin, E.F. El-Saadany, M.M.A. Salama, Intentional islanding of distributed generation IEEE Power Engineering Society General Meeting, 2005. pp. 1496- 1502 ,(2005) , 10.1109/PES.2005.1489218
C. Rowland, D. Smaha, J. Pope, Coordination of Load Conservation with Turbine-Generator Underfrequency Protection IEEE Transactions on Power Apparatus and Systems. ,vol. 99, pp. 1137- 1150 ,(1980) , 10.1109/TPAS.1980.319744
Md. Quamrul Ahsan, Abdul Hasib Chowdhury, S. Shahnawaz Ahmed, Imamul Hassan Bhuyan, Mohammad Ariful Haque, Hamidur Rahman, Technique to Develop Auto Load Shedding and Islanding Scheme to Prevent Power System Blackout IEEE Transactions on Power Systems. ,vol. 27, pp. 198- 205 ,(2012) , 10.1109/TPWRS.2011.2158594
Rafael R Londero, Carolina M Affonso, Marcus VA Nunes, Walmir Freitas, None, Planned islanding for Brazilian system reliability ieee/pes transmission and distribution conference and exposition. pp. 1- 6 ,(2010) , 10.1109/TDC.2010.5484251
N. Grudinin, I. Roytelman, Heading off emergencies in large electric grids IEEE Spectrum. ,vol. 34, pp. 42- 47 ,(1997) , 10.1109/MSPEC.1997.583446
Pukar Mahat, Zhe Chen, Birgitte Bak-Jensen, Underfrequency Load Shedding for an Islanded Distribution System With Distributed Generators IEEE Transactions on Power Delivery. ,vol. 25, pp. 911- 918 ,(2010) , 10.1109/TPWRD.2009.2032327
Pradit Fuangfoo, Wei-Jen Lee, Ming-Tse Kuo, Impact Study on Intentional Islanding of Distributed Generation Connected to a Radial Subtransmission System in Thailand's Electric Power System ieee industry applications society annual meeting. ,vol. 43, pp. 1491- 1498 ,(2006) , 10.1109/TIA.2007.908184
Haibo You, V. Vittal, Zhong Yang, Self-healing in power systems: an approach using islanding and rate of frequency decline-based load shedding IEEE Transactions on Power Systems. ,vol. 18, pp. 174- 181 ,(2002) , 10.1109/TPWRS.2002.807111
B. Delfino, S. Massucco, A. Morini, P. Scalera, F. Silvestro, Implementation and comparison of different under frequency load-shedding schemes power engineering society summer meeting. ,vol. 1, pp. 307- 312 ,(2001) , 10.1109/PESS.2001.970031