A brief review of parallel magnetic resonance imaging

作者: Robin M. Heidemann , �zkan �zsarlak , Paul M. Parizel , Johan Michiels , Berthold Kiefer

DOI: 10.1007/S00330-003-1992-7

关键词:

摘要: … Magnetic resonance imaging has progressed at a spectacular rate since the 1980s and still represents a continually evolving medical technology. Presently, MRI, with its excellent …

参考文章(31)
Mathias Nittka, Berthold Kiefer, Mark A. Griswold, Peter M. Jakob, Jianmin Wang, Robin M. Heidemann, A. Haase, Off-resonance artifacts in single shot EPI using partially parallel imaging pp. 446- 446 ,(2001)
Mathias Nittka, Berthold Kiefer, Mark A. Griswold, Axel Haase, Peter M. Jakob, Jianmin Wang, David A. Porter, Robin M. Heidemann, Minimizing Distortions and Blurring in Diffusion Weighted Single Shot EPI using High Performance Gradients in Combination with Parallel Imaging pp. 169- 169 ,(2001)
Mark A. Griswold, A Benfield, Axel Haase, Peter M. Jakob, Robin M. Heidemann, General considerations about the CNR in diffusion weighted EPI using partially parallel acquisition methods pp. 2414- 2414 ,(2001)
J.W Carlson, An algorithm for NMR imaging reconstruction based on multiple RF receiver coils Journal of Magnetic Resonance. ,vol. 74, pp. 376- 380 ,(1987) , 10.1016/0022-2364(87)90348-9
Roland Bammer, Stephen L. Keeling, Michael Augustin, Klaas P. Pruessmann, Roswitha Wolf, Rudolf Stollberger, Hans-Peter Hartung, Franz Fazekas, Improved diffusion-weighted single-shot echo-planar imaging (EPI) in stroke using sensitivity encoding (SENSE). Magnetic Resonance in Medicine. ,vol. 46, pp. 548- 554 ,(2001) , 10.1002/MRM.1226
R Todd Constable, John C Gore, None, The loss of small objects in variable TE imaging: implications for FSE, RARE, and EPI. Magnetic Resonance in Medicine. ,vol. 28, pp. 9- 24 ,(1992) , 10.1002/MRM.1910280103
J. W. Carlson, T. Minemura, Imaging time reduction through multiple receiver coil data acquisition and image reconstruction Magnetic Resonance in Medicine. ,vol. 29, pp. 681- 687 ,(1993) , 10.1002/MRM.1910290516
Michael Hutchinson, Ulrich Raff, Fast MRI data acquisition using multiple detectors Magnetic Resonance in Medicine. ,vol. 6, pp. 87- 91 ,(1988) , 10.1002/MRM.1910060110
Mark A. Griswold, Peter M. Jakob, Mathias Nittka, James W. Goldfarb, Axel Haase, Partially parallel imaging with localized sensitivities (PILS). Magnetic Resonance in Medicine. ,vol. 44, pp. 602- 609 ,(2000) , 10.1002/1522-2594(200010)44:4<602::AID-MRM14>3.0.CO;2-5
Markus Weiger, Klaas P. Pruessmann, Andrea Kassner, Giles Roditi, Tristan Lawton, Allan Reid, Peter Boesiger, Contrast-enhanced 3D MRA using SENSE. Journal of Magnetic Resonance Imaging. ,vol. 12, pp. 671- 677 ,(2000) , 10.1002/1522-2586(200011)12:5<671::AID-JMRI3>3.0.CO;2-F