On ultrasound image reconstruction by tissue density estimation

作者: Zheng Huang , Jingxin Zhang , Cishen Zhang

DOI: 10.1109/ICCA.2010.5524511

关键词:

摘要: An inherent property of medical ultrasound imaging is the speckle noise that generally obscures image and reduces diagnostic resolution contrast. Consequently, substantial improvement images an important prerequisite for imaging. Some recent research has suggested spatial distribution tissue densities may be used in to reconstruct with fewer speckles. This new approach based on direct estimation density from radio frequency echo signals received by probe. paper presents a mathematical analysis this derives simplified model issue estimation. simplifies computation involved provides deeper insight into problem. It shows reconstruction have limited effect embedded RF signal. The results are verified numerical calculations simulation examples.

参考文章(17)
J Jensen, Estimation of in vivo pulses in medical ultrasound. Ultrasonic Imaging. ,vol. 16, pp. 190- 203 ,(1994) , 10.1006/UIMG.1994.1012
Peter R. Stepanishen, Pulsed transmit/receive response of ultrasonic piezoelectric transducers Journal of the Acoustical Society of America. ,vol. 69, pp. 1815- 1827 ,(1981) , 10.1121/1.385919
Peter R. Stepanishen, Transient Radiation from Pistons in an Infinite Planar Baffle The Journal of the Acoustical Society of America. ,vol. 49, pp. 1629- 1638 ,(1971) , 10.1121/1.1912541
Ming Chen, Cishen Zhang, Discrete echo signal modeling of ultrasound imaging systems Medical Imaging 2008: Ultrasonic Imaging and Signal Processing. ,vol. 6920, pp. 692008- ,(2008) , 10.1117/12.769956
Jo/rgen Arendt Jensen, A model for the propagation and scattering of ultrasound in tissue The Journal of the Acoustical Society of America. ,vol. 89, pp. 182- 190 ,(1991) , 10.1121/1.400497
K. G. Boone, D. S. Holder, Effect of skin impedance on image quality and variability in electrical impedance tomography: a model study Medical & Biological Engineering & Computing. ,vol. 34, pp. 351- 353 ,(1996) , 10.1007/BF02520003
Oleg Michailovich, Allen Tannenbaum, Blind Deconvolution of Medical Ultrasound Images: A Parametric Inverse Filtering Approach IEEE Transactions on Image Processing. ,vol. 16, pp. 3005- 3019 ,(2007) , 10.1109/TIP.2007.910179
T. Taxt, Restoration of medical ultrasound images using two-dimensional homomorphic deconvolution IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control. ,vol. 42, pp. 543- 554 ,(1995) , 10.1109/58.393097
T. Taxt, J. Strand, Two-dimensional noise-robust blind deconvolution of ultrasound images IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control. ,vol. 48, pp. 861- 866 ,(2001) , 10.1109/58.935701
R. Jirik, T. Taxt, High-resolution ultrasonic imaging using two-dimensional homomorphic filtering IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control. ,vol. 53, pp. 1440- 1448 ,(2006) , 10.1109/TUFFC.2006.1665101