作者: B Marandet , G Sanz
DOI: 10.1520/STP35555S
关键词:
摘要: The critical value J 1 c and the apparent fracture toughness K B d are measured with a single small specimen (compact tension or three-point-bend bar) loaded in elastic-plastic range. Initiation is detected during loading by an electrical potential method. For steels studied here (2.25Cr-lMo, electroslag weld, manganese cast steel), values deduced from agreement directly thick specimens transition-temperature Furthermore, equivalent energy procedure gives same results as those obtained J-integral