作者: J.E. Fletcher , B.W. Williams , T.C. Green
关键词:
摘要: Static and dynamic core loss tests for a synchronous reluctance machine are reported. The effect of inductance ripple has been found to increase the actual losses apparent under specific flux frequency conditions. Using curve fitting, simple model derived from experimental data. This used compare steady state performance constant current angle control strategies using DSP controlled drive system. strategy displays an efficiency advantage over significant portion base speed operating range,. >