Use of a Voltammetric Electronic Tongue for Detection and Classification of Nerve Agent Mimics

作者: Inmaculada Campos , Luis Gil , Ramón Martínez-Mañez , Juan Soto , José-Luis Vivancos

DOI: 10.1002/ELAN.200900625

关键词:

摘要: An electronic tongue (ET) based on pulse voltammetry has been used to predict the presence of nerve agent mimics in aqueous environments. The array consists eight working electrodes (Au, Pt, Ir, Rh, Cu, Co, Ni and Ag) encapsulated a stainless steel cylinder. Studies including principal component analysis (PCA), artificial neural networks (fuzzy ARTMAP) partial least square techniques (PLS) have applied for data management prediction models. For instance is able discriminate simulants diethyl chlorophosphate (DCP) cyanophosphate (DCNP) from other organophosphorous derivatives water. Finally, PLS using system 3 compounds concentration levels shows good accuracy DCP DCNP

参考文章(38)
B JOO, J HUH, D LEE, Fabrication of polymer SAW sensor array to classify chemical warfare agents Sensors and Actuators B-chemical. ,vol. 121, pp. 47- 53 ,(2007) , 10.1016/J.SNB.2006.09.013
A.T. Nimal, Upendra Mittal, Mohan Singh, Mamta Khaneja, G.K. Kannan, J.C. Kapoor, Vinita Dubey, P.K. Gutch, Gobardhan Lal, K.D. Vyas, D.C. Gupta, Development of handheld SAW vapor sensors for explosives and CW agents Sensors and Actuators B: Chemical. ,vol. 135, pp. 399- 410 ,(2009) , 10.1016/J.SNB.2008.08.040
A.L Simonian, J.K Grimsley, A.W Flounders, J.S Schoeniger, Tu-Chen Cheng, J.J DeFrank, J.R Wild, Enzyme-based biosensor for the direct detection of fluorine-containing organophosphates Analytica Chimica Acta. ,vol. 442, pp. 15- 23 ,(2001) , 10.1016/S0003-2670(01)01131-X
Xiaosong Du, Zhihua Ying, Yadong Jiang, Zhongxiang Liu, Taojun Yang, Guangzhong Xie, Synthesis and evaluation of a new polysiloxane as SAW sensor coatings for DMMP detection Sensors and Actuators B-chemical. ,vol. 134, pp. 409- 413 ,(2008) , 10.1016/J.SNB.2008.05.016
Susanne Holmin, Per Spångeus, Christina Krantz-Rülcker, Fredrik Winquist, Compression of electronic tongue data based on voltammetry — a comparative study Sensors and Actuators B: Chemical. ,vol. 76, pp. 455- 464 ,(2001) , 10.1016/S0925-4005(01)00585-8
Chang Wang, Sigang Xie, Jun Yang, Qing Yang, Guowang Xu, Structural identification of human blood phospholipids using liquid chromatography/quadrupole-linear ion trap mass spectrometry Analytica Chimica Acta. ,vol. 525, pp. 1- 10 ,(2004) , 10.1016/J.ACA.2004.07.065
Roberto H. Labrador, John Olsson, Fredrik Winquist, Ramón Martínez-Máñez, Juan Soto, Determination of Bisulfites in Wines with an Electronic Tongue Based on Pulse Voltammetry Electroanalysis. ,vol. 21, pp. 612- 617 ,(2009) , 10.1002/ELAN.200804457
Honglae Sohn, Sonia Létant, Michael J. Sailor, William C. Trogler, Detection of Fluorophosphonate Chemical Warfare Agents by Catalytic Hydrolysis with a Porous Silicon Interferometer Journal of the American Chemical Society. ,vol. 122, pp. 5399- 5400 ,(2000) , 10.1021/JA0006200
Alexey A. Tomchenko, Gregory P. Harmer, Brent T. Marquis, Detection of chemical warfare agents using nanostructured metal oxide sensors Sensors and Actuators B-chemical. ,vol. 108, pp. 41- 55 ,(2005) , 10.1016/J.SNB.2004.11.059