Continuous-time identification of a PWM aerated bench scale activated sludge reactor using state-variable filters

作者: Freud S. B. C. Lima , Francisco J. S. Silva , Sebastian Y. C. Catunda , Joao V. da Fonseca Neto

DOI: 10.1109/IMTC.2011.5944304

关键词:

摘要: In activated sludge systems the dissolved oxygen dynamics have been seen as main information source for online state estimation. Then, most accurate models can improve quality of estimations and consequently measurement system. this paper a bench scale aerobic reactor model is developed by including related with aeration system operation probe. The operated aquarium air pumps, which must be turned on needed. procedure estimating parameters presented. Simulations are presented illustrating proposed model. estimated from experimental results using at laboratory.

参考文章(11)
Robert H. Kohr, A Method for the Determination of a Differential Equation Model for Simple Nonlinear Systems IEEE Transactions on Electronic Computers. ,vol. 12, pp. 394- 400 ,(1963) , 10.1109/PGEC.1963.263471
V.V. Lira, P.R. Barros, J.S. da Rocha Neto, A.C. van Haandel, Estimation of dissolved oxygen dynamics for sequencing batch aerobic reactors instrumentation and measurement technology conference. ,vol. 1, pp. 14- 19 ,(2004) , 10.1109/IMTC.2004.1350984
S.Y.C. Catunda, G.S. Deep, A.C. van Haandel, R.C.S. Freire, Feedback control method for estimating the oxygen uptake rate in activated sludge systems IEEE Transactions on Instrumentation and Measurement. ,vol. 48, pp. 864- 869 ,(1999) , 10.1109/19.779191
Francisco J. S. Silva, Sebastian Y. C. Catunda, Joao V. Fonseca Neto, Adrianus C. van Haandel, Dissolved oxygen PWM control and oxygen uptake rate estimation using Kalman Filter in activated sludge systems instrumentation and measurement technology conference. pp. 579- 584 ,(2010) , 10.1109/IMTC.2010.5488094