作者: Dr. Ghalib. Y. Kahwaji , Dr. A. R. Habbo Mohammed
DOI: 10.33899/RENGJ.2005.46203
关键词:
摘要: A thermodynamic simulation of the power generation gas turbine Mosul station was carried out, and its performance observed. The included detailed modeling compressor, combustion chamber based on physics as well common practice in field. Comparison code results with field collected data indicated agreement to within 2% compared parameters. developed then used study effect varying ambient temperature system. showed a decrease up 21% output when increases from ISO value 15 ˚C 45 ˚C. between running system under constant inlet were also conducted.