作者: Deepali Kamthania , Sujata Nayak , G.N. Tiwari
DOI: 10.1016/J.ENBUILD.2011.05.007
关键词:
摘要: Abstract This paper presents the performance evaluation of a hybrid photovoltaic thermal (Semi transparent PVT) double pass facade for space heating. The model has been developed by using energy balance equations proposed under quasi-steady state condition. Numerical computations have carried out composite climate New Delhi, India. An analysis to calculate annual and exergy gain facade. On basis numerical results it observed that electrical are 480.81 kWh 469.87 kWh respectively. yearly overall generated system calculated as 1729.84 kWh. It is also room air temperature increases 5–6 °C than ambient typical winter day.