MRI based assessment of the extent to which stereo-tracking of markers on the chest can predict motion of the heart

作者: Michael A. King , Joyoni Dey , Joseph E. McNamara , Karen Johnson , Joyeeta Mitra

DOI: 10.1109/NSSMIC.2008.4774236

关键词:

摘要: We have developed a visual-tracking-system (VTS) which uses stereo-imaging to track the motion of markers on patients during cardiac SPECT imaging with goal using tracked correct for patient motion. The aim this study is determine MRI in volunteers if rigid-body-motion (RBM) model can be used predict heart within chest from surface chest. Our methodology investigating body-motion separate influence respiration volunteer hold their breath acquisition sequence 2 sets EKG-triggered sagittal slices covering heart, first set pre-motion and second post-motion. link these studies such that process takes ∼ 45 seconds initiation till given instruction resume breathing. An analysis combined individual obtain an estimate six-degree-of-freedom (6DOF) RBM volunteer. estimated by semi-automatic 3D segmentation region subsequent registration slices. Studies did not intentionally move between acquisitions were establish baseline agreement methods estimation small motions. VTS estimates was good “no-motion” case maximum difference ≪ 5 mm any translation component, ≪2 deg rotational component. With body translations as axial-slide might expected approximate RBM, also being 6 mm, 2.5 deg. Application non-RBM counter-clock-wise (CCW) twist at shoulders hips fixed, decreased magnitude misalignment caused but same extent previous classes differences class motions ≪11 4.5 angular. Thus use predictions correction reconstruction should decrease artifacts types studied, less so those are better modeled non-RBM.

参考文章(20)
Brian K. McCandless, Jeffrey A. Cooper, Paul H. Neumann, Effect of patient motion on tomographic myocardial perfusion imaging. The Journal of Nuclear Medicine. ,vol. 33, pp. 1566- 1571 ,(1992)
Catalin Loghin, Stefano Sdringola, K. Lance Gould, Common Artifacts in PET Myocardial Perfusion Images Due to Attenuation–Emission Misregistration: Clinical Significance, Causes, and Solutions The Journal of Nuclear Medicine. ,vol. 45, pp. 1029- 1039 ,(2004)
Joyoni Dey, Tin-Su Pan, David J. Choi, Mark Smyczynski, Hendrik Pretorius, Michael A. King, Knowledge-based segmentation of the heart from respiratory-gated CT datasets acquired without cardiac contrast-enhancement Progress in biomedical optics and imaging. ,vol. 6144, pp. 614409- ,(2006) , 10.1117/12.655742
L LEMEUNIER, R MAASSMORENO, J CARRASQUILLO, W DIECKMANN, S BACHARACH, PET/CT imaging: effect of respiratory motion on apparent myocardial uptake. Journal of Nuclear Cardiology. ,vol. 13, pp. 821- 830 ,(2006) , 10.1016/J.NUCLCARD.2006.09.003
Joseph E. McNamara, P. Hendrik Pretorius, Karen Johnson, Joyeeta Mitra Mukherjee, Joyoni Dey, Michael A. Gennert, Michael A. King, A flexible multicamera visual-tracking system for detecting and correcting motion-induced artifacts in cardiac SPECT slices Medical Physics. ,vol. 36, pp. 1913- 1923 ,(2009) , 10.1118/1.3117592
Joyeeta Mitra, Joseph E. McNamara, Karen L. Johnson, Joyoni Dey, Michael A. King, Estimation of rigid-body and respiratory motion of the heart for SPECT motion correction ieee nuclear science symposium. ,vol. 5, pp. 3570- 3576 ,(2007) , 10.1109/NSSMIC.2007.4436897
Richard D. Beach, Hans Depold, Guido Boening, Philippe P. Bruyant, Bing Feng, Howard C. Gifford, Michael A. Gennert, Suman Nadella, Michael A. King, An Adaptive Approach to Decomposing Patient-Motion Tracking Data Acquired During Cardiac SPECT Imaging IEEE Transactions on Nuclear Science. ,vol. 54, pp. 130- 139 ,(2007) , 10.1109/TNS.2006.887471
A.Z. Kyme, B.F. Hutton, R.L. Hatton, D.W. Skerrett, L.R. Barnden, Practical aspects of a data-driven motion correction approach for brain SPECT IEEE Transactions on Medical Imaging. ,vol. 22, pp. 722- 729 ,(2003) , 10.1109/TMI.2003.814790