Non-contrast-enhanced four-dimensional (4D) intracranial MR angiography: a feasibility study.

作者: Xiaoming Bi , Peter Weale , Peter Schmitt , Sven Zuehlsdorff , Renate Jerecic

DOI: 10.1002/MRM.22220

关键词:

摘要: T1-shortening contrast agents have been widely used in time-resolved magnetic resonance angiography. To match imaging data acquisition with the short time period of first pass agent, temporal resolution and/or spatial to be compromised many cases. In this study, a novel non-contrast-enhanced technique was developed for Alternating magnetization preparation applied two consecutive acquisitions each measurement eliminate need media. Without constraint media kinetics, is drastically improved from order second as conventional contrast-enhanced approach tens milliseconds (50.9 msec) without compromising resolution. Initial results volunteer studies demonstrate feasibility method depict anatomic structure and dynamic filling main vessels head. Magn Reson Med 63:835–841, 2010. © 2010 Wiley-Liss, Inc.

参考文章(20)
M. Duran, S. Schoenberg, W. Yuh, M. Knopp, G. van Kaick, M. Essig, Cerebral arteriovenous malformations: morphologic evaluation by ultrashort 3D gadolinium-enhanced MR angiography. European Radiology. ,vol. 12, pp. 2957- 2964 ,(2002) , 10.1007/S00330-002-1418-Y
E. Mark Haacke, Robert W. Brown, Michael R. Thompson, Ramesh Venkatesan, Yu Chung N Cheng, Magnetic Resonance Imaging: Physical Principles and Sequence Design ,(1999)
Thomas J. Masaryk, Gerhard A. Laub, Michael T. Modic, Jeffrey S. Ross, E. Mark Haacke, Carotid-CNS MR flow imaging Magnetic Resonance in Medicine. ,vol. 14, pp. 308- 314 ,(1990) , 10.1002/MRM.1910140215
D. S. Williams, J. A. Detre, J. S. Leigh, A. P. Koretsky, Magnetic resonance imaging of perfusion using spin inversion of arterial water. Proceedings of the National Academy of Sciences of the United States of America. ,vol. 89, pp. 212- 216 ,(1992) , 10.1073/PNAS.89.1.212
Martin R. Prince, E. Kent Yucel, John A. Kaufman, David C. Harrison, Stuart C. Geller, Dynamic gadolinium‐enhanced three‐dimensional abdominal MR arteriography Journal of Magnetic Resonance Imaging. ,vol. 3, pp. 877- 881 ,(1993) , 10.1002/JMRI.1880030614
John G. Sled, G. Bruce Pike, Quantitative imaging of magnetization transfer exchange and relaxation properties in vivo using MRI. Magnetic Resonance in Medicine. ,vol. 46, pp. 923- 931 ,(2001) , 10.1002/MRM.1278
Charles A. Mistretta, Thomas M. Grist, Frank R. Korosec, Richard Frayne, Dana C. Peters, Yousef Mazaheri, Timothy J. Carroll, 3D Time‐resolved contrast‐enhanced MR DSA: Advantages and tradeoffs Magnetic Resonance in Medicine. ,vol. 40, pp. 571- 581 ,(1998) , 10.1002/MRM.1910400410
Patricia J. Nelemans, Tim Leiner, Henrica C. W. de Vet, Joseph M. A. van Engelshoven, Peripheral Arterial Disease: Meta-analysis of the Diagnostic Performance of MR Angiography Radiology. ,vol. 217, pp. 105- 114 ,(2000) , 10.1148/RADIOLOGY.217.1.R00OC11105
Dwight G. Nishimura, Albert Macovski, John M. Pauly, Steven M. Conolly, MR angiography by selective inversion recovery. Magnetic Resonance in Medicine. ,vol. 4, pp. 193- 202 ,(1987) , 10.1002/MRM.1910040214