Evaluation of Precision and Accuracy Assessment of Different 3-D Surface Imaging Systems for Biomedical Purposes

作者: Maximilian Eder , Gernot Brockmann , Alexander Zimmermann , Moschos A. Papadopoulos , Katja Schwenzer-Zimmerer

DOI: 10.1007/S10278-012-9487-1

关键词:

摘要: Three-dimensional (3-D) surface imaging has gained clinical acceptance, especially in the field of cranio-maxillo-facial and plastic, reconstructive, aesthetic surgery. Six scanners based on different scanning principles (Minolta Vivid 910®, Polhemus FastSCAN™, GFM PRIMOS®, TopoCAM®, Steinbichler Comet® Vario Zoom 250, 3dMD DSP 400®) were used to measure five sheep skulls sizes. In three areas with varying anatomical complexity (areas, 1 = high; 2 = moderate; 3 = low), 56 distances between 20 landmarks are defined each skull. Manual measurement (MM), coordinate machine measurements (CMM) computer tomography (CT) define a reference method for further precision accuracy evaluation 3-D systems. MM showed high correlation CMM CT (both r = 0.987; p < 0.001) served as method. 910® highest over all complexity; 400® demonstrated being most accurate 1 3, area 2. accordance measured distance length, devices present higher large lower degrees short distances. general, associated assessment accuracy, suggesting that optimal results, types should be applied specific applications medical problems according their special construction designs characteristics.

参考文章(27)
R. E. Giunta, M. Eder, H.-G. Machens, D. F. Müller, L. Kovacs, Structural fat grafting for rejuvenation of the dorsum of the hand Handchirurgie Mikrochirurgie Plastische Chirurgie. ,vol. 42, pp. 143- 147 ,(2010) , 10.1055/S-0030-1249039
Francesca Frexia, Tibor Balogh, Tamas Forgacs, Fabio Bettio, Gianluigi Zanetti, Enrico Gobbetti, Giovanni Pintore, Andrea Giachetti, Eric Bouvier, Tibor Agocs, A holographic collaborative medical visualization system. Studies in health technology and informatics. ,vol. 119, pp. 52- ,(2006)
Laszlo Kovacs, Alexander Yassouridis, Alexander Zimmermann, Gernot Brockmann, Antonia W??hnl, Matthias Blaschke, Maximilian Eder, Katja Schwenzer-Zimmerer, Robert Rosenberg, Nikolaos A. Papadopulos, Edgar Biemer, Optimization of 3-dimensional imaging of the breast region with 3-dimensional laser scanners Annals of Plastic Surgery. ,vol. 56, pp. 229- 236 ,(2006) , 10.1097/01.SAP.0000197774.80832.24
C. Hoehnke, M. Eder, N.A. Papadopulos, A. Zimmermann, G. Brockmann, E. Biemer, L. Kovacs, Minimal invasive reconstruction of posttraumatic hemi facial atrophy by 3-D computer-assisted lipofilling. Journal of Plastic Reconstructive and Aesthetic Surgery. ,vol. 60, pp. 1138- 1144 ,(2007) , 10.1016/J.BJPS.2007.01.068
Kevin Bush, Oleh Antonyshyn, Three-dimensional facial anthropometry using a laser surface scanner : Validation of the technique Plastic and Reconstructive Surgery. ,vol. 98, pp. 226- 235 ,(1996) , 10.1097/00006534-199608000-00004
Laszlo Kovacs, Maximilian Eder, Regina Hollweck, Alexander Zimmermann, Markus Settles, Armin Schneider, Kristian Udosic, Katja Schwenzer-Zimmerer, Nikolaos A. Papadopulos, Edgar Biemer, New aspects of breast volume measurement using 3-dimensional surface imaging. Annals of Plastic Surgery. ,vol. 57, pp. 602- 610 ,(2006) , 10.1097/01.SAP.0000235455.21775.6A
G. Brockmann, A. Zimmermann, N.A. Papadopulos, M.A. Papadopoulos, L. Kovacs, Evaluation of applicability and accuracy of different surface scanning systems in medicine Journal of Biomechanics. ,vol. 39, ,(2006) , 10.1016/S0021-9290(06)85354-6
L. Kovacs, A. Zimmermann, G. Brockmann, M. Gühring, H. Baurecht, N.A. Papadopulos, K. Schwenzer-Zimmerer, R. Sader, E. Biemer, H.F. Zeilhofer, Three-dimensional recording of the human face with a 3D laser scanner Journal of Plastic, Reconstructive & Aesthetic Surgery. ,vol. 59, pp. 1193- 1202 ,(2006) , 10.1016/J.BJPS.2005.10.025
B.D. Bradley, A.D.C. Chan, M.J.D. Hayes, A 3D scanning system for biomedical purposes International Journal of Advanced Media and Communication. ,vol. 3, pp. 35- 54 ,(2009) , 10.1504/IJAMC.2009.026851
K. Schwenzer-Zimmerer, J. Haberstok, L. Kovacs, B. I. Boerner, N. Schwenzer, P. Juergens, H.-F. Zeilhofer, C. Holberg, 3D Surface Measurement for Medical Application--Technical Comparison of Two Established Industrial Surface Scanning Systems Journal of Medical Systems. ,vol. 32, pp. 59- 64 ,(2008) , 10.1007/S10916-007-9108-6