Image Visualization and Post-processing Techniques

作者: Bernd M Ohnesorge , Thomas G Flohr , Christoph R Becker , Andreas Knez , Maximilian F Reiser

DOI: 10.1007/978-3-540-49546-8_6

关键词:

摘要:

参考文章(23)
Alexander W Leber, Andreas Knez, Alexander Becker, Christoph Becker, Franz von Ziegler, Konstantin Nikolaou, Carsten Rist, Maximilian Reiser, Carl White, Gerhard Steinbeck, Peter Boekstegers, Accuracy of multidetector spiral computed tomography in identifying and differentiating the composition of coronary atherosclerotic plaques. A comparative study with intracoronary ultrasound Journal of the American College of Cardiology. ,vol. 43, pp. 1241- 1247 ,(2004) , 10.1016/J.JACC.2003.10.059
Stephen Schroeder, Andreas F Kopp, Andreas Baumbach, Christoph Meisner, Axel Kuettner, Christian Georg, Bernd Ohnesorge, Christian Herdeg, Claus D Claussen, Karl R Karsch, Noninvasive detection and evaluation of atherosclerotic coronary plaques with multislice computed tomography11This study was performed without additional financial support. Journal of the American College of Cardiology. ,vol. 37, pp. 1430- 1435 ,(2001) , 10.1016/S0735-1097(01)01115-9
Stefan Ulzheimer, Willi A. Kalender, Assessment of calcium scoring performance in cardiac computed tomography. European Radiology. ,vol. 13, pp. 484- 497 ,(2003) , 10.1007/S00330-002-1746-Y
Kimberly A. Addis, Kenneth D. Hopper, Tunç A. Iyriboz, Yi Liu, Scott W. Wise, Claudia J. Kasales, Judy S. Blebea, David T. Mauger, CT Angiography American Journal of Roentgenology. ,vol. 177, pp. 1171- 1176 ,(2001) , 10.2214/AJR.177.5.1771171
Stephen Devries, Christopher Wolfkiel, Vijay Shah, Eva Chomka, Stuart Rich, Reproducibility of the measurement of coronary calcium with ultrafast computed tomography American Journal of Cardiology. ,vol. 75, pp. 973- 975 ,(1995) , 10.1016/S0002-9149(99)80706-1
A. H. Mahnken, J. E. Wildberger, A. M. Sinha, K. Dedden, S. Stanzel, R. Hoffmann, T. Schmitz-Rode, R. W. Gunther, Value of 3D-volume rendering in the assessment of coronary arteries with retrospectively ECG-gated multislice spiral CT. Acta Radiologica. ,vol. 44, pp. 302- 309 ,(2003) , 10.1034/J.1600-0455.2003.00057.X
T Flohr, K Stierstorfer, R Raupach, S Ulzheimer, H Bruder, Performance evaluation of a 64-slice CT system with z-flying focal spot. Rofo-fortschritte Auf Dem Gebiet Der Rontgenstrahlen Und Der Bildgebenden Verfahren. ,vol. 176, pp. 1803- 1810 ,(2004) , 10.1055/S-2004-813717
B Ohnesorge, T Flohr, R Fischbach, A Kopp, A Knez, S Schröder, U Schöpf, A Crispin, E Klotz, M Reiser, C Becker, None, Reproducibility of coronary calcium quantification in repeat examinations with retrospectively ECG-gated multisection spiral CT. European Radiology. ,vol. 12, pp. 1532- 1540 ,(2002) , 10.1007/S00330-002-1394-2
Andreas H. Mahnken, Marcus Katoh, Philipp Bruners, Elmar Spuentrup, Joachim E. Wildberger, Rolf W. Günther, Arno Buecker, Acute myocardial infarction: assessment of left ventricular function with 16-detector row spiral CT versus MR imaging--study in pigs. Radiology. ,vol. 236, pp. 112- 117 ,(2005) , 10.1148/RADIOL.2361040923
Raghav Raman, Sandy Napel, Geoffrey D. Rubin, Curved-Slab Maximum Intensity Projection: Method and Evaluation Radiology. ,vol. 229, pp. 255- 260 ,(2003) , 10.1148/RADIOL.2291020370