Analytical behavior of eccentrically loaded concrete encased steel columns subjected to standard fire including cooling phase

作者: Er-Feng Du , Gan-Ping Shu , Xiao-Yong Mao

DOI: 10.1007/S13296-013-1012-Y

关键词:

摘要: A nonlinear 3-D finite element analysis (FEA) model was developed to predict the behavior of eccentrically loaded concrete encased steel (CES) columns subjected ISO-834 standard fire including heating and cooling phases. The has been validated against published tests conducted at elevated temperatures. Comparisons between predicted results test show that this can accurately CES under fire. FEA then used investigate typical temperature-time curve mid-height lateral deformation-time eccentric compression in a complete loading history initial loading, cooling. It is shown temperature delay obvious inner layers concrete. resistance column should be checked for full process exposure until temperatures everywhere start decrease. deformation still gradually increases during phase may fail phase. There large residual after exposure. Furthermore, variables influence were investigated parametric studies. found main parameters which are load ratio, slenderness duration time, depth width ratio cross-sectional ratio.

参考文章(12)
Ehab Ellobody, Ben Young, Investigation of concrete encased steel composite columns at elevated temperatures Thin-walled Structures. ,vol. 48, pp. 597- 608 ,(2010) , 10.1016/J.TWS.2010.03.004
Jiang-Tao Yu, Zhou-Dao Lu, Qun Xie, Nonlinear analysis of SRC columns subjected to fire Fire Safety Journal. ,vol. 42, pp. 1- 10 ,(2007) , 10.1016/J.FIRESAF.2006.06.006
Xiaoyong Mao, V.K.R. Kodur, Fire resistance of concrete encased steel columns under 3- and 4-side standard heating Journal of Constructional Steel Research. ,vol. 67, pp. 270- 280 ,(2011) , 10.1016/J.JCSR.2010.11.006
Tian-Yi Song, Lin-Hai Han, Hong-Xia Yu, Temperature Field Analysis of SRC-Column to SRC-Beam Joints Subjected to Simulated Fire Including Cooling Phase: Advances in Structural Engineering. ,vol. 14, pp. 353- 366 ,(2011) , 10.1260/1369-4332.14.3.353
Zhi-Hua Wang, Kang Hai Tan, Residual area method for heat transfer analysis of concrete-encased I-sections in fire Engineering Structures. ,vol. 28, pp. 411- 422 ,(2006) , 10.1016/J.ENGSTRUCT.2005.08.013
Zhan-Fei Huang, Kang-Hai Tan, Guan-Hwee Phng, Axial restraint effects on the fire resistance of composite columns encasing I-section steel Journal of Constructional Steel Research. ,vol. 63, pp. 437- 447 ,(2007) , 10.1016/J.JCSR.2006.07.001
H L MALHOTRA, R F STEVENS, , , FIRE RESISTANCE OF ENCASED STEEL STANCHIONS. Proceedings of the Institution of Civil Engineers. ,vol. 27, pp. 77- 98 ,(1964) , 10.1680/IICEP.1964.10371
Mao Xiao-yong, Calculation of Temperature Field of Steel Reinforced Concrete Columns under Fire Journal of University of Science and Technology of Suzhou. ,(2009)
Zhang Bin, Research on the Fire Resistant Capacity of Eccentric Loaded SRC Columns Progress in Steel Building Structures. ,(2006)