Manufacturing hollow obturator with resilient denture liner on post hemimaxillectomy

作者: Michael Josef Kridanto Kamadjaja

DOI: 10.20473/J.DJMKG.V39.I1.P16-18

关键词:

摘要: A resilient denture liner is placed in the part of hollow obturator base that contacts to post hemimaxillectomy mucosa. Replacing can makes has an intimate contact with mucosa, so it prevents mouth liquid enter cavum nasi and sinus, also eliminates painful because using obturator. Resilient a soft material applied fitting surface order allow more distribution load. case was reported about on overcome these problems.

参考文章(11)
A Harrison, R Huggett, S Qudah, Soft lining materials in prosthetic dentistry: a review International Journal of Prosthodontics. ,vol. 3, pp. 477- 483 ,(1990)
Alan B. Carr, David T. Brown, Glen P. McGivney, McCracken's Removable partial prosthodontics ,(1973)
Mohamed A. Aramany, Basic principles of obturator design for partially edentulous patients. Part II: Design principles Journal of Prosthetic Dentistry. ,vol. 40, pp. 656- 662 ,(1978) , 10.1016/0022-3913(78)90065-3
Ronald P. Desjardins, Obturator prosthesis design for acquired maxillary defects Journal of Prosthetic Dentistry. ,vol. 39, pp. 424- 435 ,(1978) , 10.1016/S0022-3913(78)80161-9
Kenneth E. Brown, Peripheral consideration in improving obturator retention. Journal of Prosthetic Dentistry. ,vol. 20, pp. 176- 181 ,(1968) , 10.1016/0022-3913(68)90143-1
Mohamed A. Aramany, Basic principles of obturator design for partially edentulous patients. Part I: classification. Journal of Prosthetic Dentistry. ,vol. 40, pp. 554- 557 ,(1978) , 10.1016/0022-3913(78)90092-6
Igor J. Pesun, James Hodges, Juey H. Lai, Effect of finishing and polishing procedures on the gap width between a denture base resin and two long-term, resilient denture liners Journal of Prosthetic Dentistry. ,vol. 87, pp. 311- 318 ,(2002) , 10.1067/MPR.2002.122162
G.A. Lammie, R. Storer, A preliminary report on resilient denture plastics Journal of Prosthetic Dentistry. ,vol. 8, pp. 411- 424 ,(1958) , 10.1016/0022-3913(58)90067-2
Tsuyoshi Takato, Takashi Ohyama, Shogo Ozawa, Hisashi Taniguchi, Hitoshi Mukohyama, Meiko Oki, Makio Kobayashi, Takaaki Inoue, Vibration analysis of obturator prostheses with different bulb height designs. Journal of medical and dental sciences. ,vol. 49, pp. 121- 128 ,(2002) , 10.11480/JMDS.490403
William F. Schmidt, Dale E. Smith, A six-year retrospective study of Molloplast-B-lined dentures. Part II: Liner serviceability. Journal of Prosthetic Dentistry. ,vol. 50, pp. 459- 465 ,(1983) , 10.1016/0022-3913(83)90563-2