QCM study of microbiological activity during long-term exposure to atmosphere—aluminium colonisation by Aspergillus Niger

作者: Povilas Miečinskas , Konstantinas Leinartas , Virginija Uksienė , Eimutis Juzeliūnas

DOI: 10.1007/S10008-007-0286-4

关键词:

摘要: The study demonstrated a possibility to sense the activity of microorganisms on metals in situ under atmosphere conditions using quartz crystal microbalance (QCM) as sensitive mass change detector. Other innovative aspects QCM application include long-term monitoring (over month), taking count influence atmospheric pressure and Al-glued foil electrodes. research subject was aluminium colonisation by Aspergillus niger Tiegh., filamentous ascomycete fungus. difference between data for abiotic biotic samples reflected microbiological activity, which resulted exponential gain during exposure. increase due various phenomena, i.e. development biomass, secretion metabolites, water uptake colony microbially induced corrosion. glued method expand scope studies from evaporated, sputtered or electroplated materials those, thin foils may be produced.

参考文章(24)
H. Ehahoun, C. Gabrielli, M. Keddam, H. Perrot, Y. Cètre, L. Diguet, Electrochemical Quartz Crystal Microbalance Corrosion Sensor for Solid Metals and Metal Alloys Application to the Dissolution of 304 Stainless Steel Journal of The Electrochemical Society. ,vol. 148, ,(2001) , 10.1149/1.1385847
M. Forslund, C. Leygraf, A Quartz Crystal Microbalance Probe Developed for Outdoor In Situ Atmospheric Corrosivity Monitoring Journal of The Electrochemical Society. ,vol. 143, pp. 839- 844 ,(1996) , 10.1149/1.1836546
Eimutis Juzeliūnas, Konstantinas Leinartas, Meilutė Samulevičienė, Aloyzas Sudavičius, Povilas Miečinskas, Remigijus Juškėnas, Vaclovas Lisauskas, Microgravimetric corrosion study of magnetron-sputtered Co-Cr-Mo and Ni-Cr-Mo alloys in an oxygen-containing atmosphere Journal of Solid State Electrochemistry. ,vol. 6, pp. 302- 310 ,(2002) , 10.1007/S100080100237
Konstantinas Leinartas, Remigijus Juškėnas, Eimutis Juzeliūnas, Asta Grigucevičienė, Structure and initial corrosion resistance of sputter deposited nanocrystalline Mg–Al–Zr alloys Materials Science and Engineering: A. ,vol. 394, pp. 411- 416 ,(2005) , 10.1016/J.MSEA.2004.11.047
Virginija Uksien≐, Konstantinas Leinartas, Remigijus Jušk≐nas, Aloyzas Sudavičius, Eimutis Juzeliūnas, Magnetron-sputtered Al–Mg coatings – structural, microgravimetric and voltammetric characterisation in water, chloride and Cu(II) environment Electrochemistry Communications. ,vol. 4, pp. 747- 752 ,(2002) , 10.1016/S1388-2481(02)00450-2
R.V Bucur, J.-O Carlsson, V.M Mecea, Quartz-crystal mass sensors with glued foil electrodes Sensors and Actuators B-chemical. ,vol. 37, pp. 91- 95 ,(1996) , 10.1016/S0925-4005(97)80075-5
Eimutis Juzeliūnas, Rimantas Ramanauskas, Albinas Lugauskas, Meilutė Samulevičienė, Konstantinas Leinartas, Microbially influenced corrosion acceleration and inhibition. EIS study of Zn and Al subjected for two years to influence of Penicillium frequentans, Aspergillus niger and Bacillus mycoides Electrochemistry Communications. ,vol. 7, pp. 305- 311 ,(2005) , 10.1016/J.ELECOM.2005.01.012