Evaluation of vertical accuracy of interocclusal records.

作者: Vassilis K Vergos , Aris-Petros D Tripodakis

DOI:

关键词:

摘要: Purpose The aim of this study was to evaluate four recording materials (polyether, polyvinyl siloxane, acrylic resin, and wax) for their ability accurately record, maintain, reproduce the vertical interocclusal relationship. Materials methods A metallic apparatus used represent opposing arches; its epoxy resin duplicate represented working casts. discrepancies produced because presence records were measured both after repositioning them on metal transferring onto Two-way ANOVA performed. Results Closure through small ranging from 24 74 microm. When repositioned apparatus, greater. lowest discrepancy displayed by siloxane (101 microm) polyether (107 microm), greatest wax (168 microm). transferred casts, approximately 0.5 mm, without significant differences among materials. Conclusion removal with clinically insignificant between tested. all tested mm found, which is clinical concern.

参考文章(11)
Chai J, Tan E, Pang Ic, A study of the surface hardness and dimensional stability of several intermaxillary registration materials. International Journal of Prosthodontics. ,vol. 7, pp. 538- ,(1994)
Beth Dawson-Saunders, Robert G. Trapp, Basic and Clinical Biostatistics ,(1993)
Veijo Lassila, Comparison of five interocclusal recording materials The Journal of Prosthetic Dentistry. ,vol. 55, pp. 215- 218 ,(1986) , 10.1016/0022-3913(86)90347-1
Aris-Petros Tripodakis, Vasilis K. Vergos, Andreas G. Tsoutsos, Evaluation of the accuracy of interocclusal records in relation to two recording techniques Journal of Prosthetic Dentistry. ,vol. 77, pp. 141- 146 ,(1997) , 10.1016/S0022-3913(97)70227-0
J. Müller, G. Götz, W. Hörz, E. Kraft, Study of the accuracy of different recording materials. Journal of Prosthetic Dentistry. ,vol. 63, pp. 41- 46 ,(1990) , 10.1016/0022-3913(90)90263-C
Veijo Lassila, John F. McCabe, Properties of interocclusal registration materials The Journal of Prosthetic Dentistry. ,vol. 53, pp. 100- 104 ,(1985) , 10.1016/0022-3913(85)90076-9
Robert A. Strohaver, A comparison of articulator mountings made with centric relation and myocentric position records. Journal of Prosthetic Dentistry. ,vol. 28, pp. 379- 390 ,(1972) , 10.1016/0022-3913(72)90239-9
Harry C. Lundeen, Centric relation records: the effect of muscle action. Journal of Prosthetic Dentistry. ,vol. 31, pp. 244- 253 ,(1974) , 10.1016/0022-3913(74)90191-7
D.C. Berry, B.P. Singh, Daily variations in occlusal contacts Journal of Prosthetic Dentistry. ,vol. 50, pp. 386- 391 ,(1983) , 10.1016/S0022-3913(83)80099-7