Thermal oxidation of CP Ti — An electrochemical and structural characterization

作者: Satendra Kumar , T.S.N. Sankara Narayanan , S. Ganesh Sundara Raman , S.K. Seshadri

DOI: 10.1016/J.MATCHAR.2010.03.002

关键词:

摘要: … In the present study commercially pure titanium (CP Ti) samples were oxidized thermally at … can be ranked as follows: CP Ti (800 C) > CP Ti (650 C) > CP Ti (500 C) > untreated CP Ti. …

参考文章(38)
Per Kofstad, High temperature corrosion Elsevier. ,(1988)
D. F. Williams, Biocompatibility of clinical implant materials CRC Press. ,(1981)
Joseph B. Harris, Search for Solutions BioScience. ,vol. 25, pp. 480- 480 ,(1975) , 10.2307/1296954
H. Guleryuz, H. Cimenoglu, Surface modification of a Ti–6Al–4V alloy by thermal oxidation Surface & Coatings Technology. ,vol. 192, pp. 164- 170 ,(2005) , 10.1016/J.SURFCOAT.2004.05.018
G. P. Burns, Titanium dioxide dielectric films formed by rapid thermal oxidation Journal of Applied Physics. ,vol. 65, pp. 2095- 2097 ,(1989) , 10.1063/1.342856
L.M. Rabbe, J. Rieu, A. Lopez, P. Combrade, Fretting deterioration of orthopaedic implant materials: search for solutions Clinical Materials. ,vol. 15, pp. 221- 226 ,(1994) , 10.1016/0267-6605(94)90049-3
Stanley A. Brown, Paula J. Hughes, Katharine Merritt, In vitro studies of fretting corrosion of orthopaedic materials Journal of Orthopaedic Research. ,vol. 6, pp. 572- 579 ,(1988) , 10.1002/JOR.1100060415
D. Velten, V. Biehl, F. Aubertin, B. Valeske, W. Possart, J. Breme, Preparation of TiO2 layers on cp‐Ti and Ti6Al4V by thermal and anodic oxidation and by sol‐gel coating techniques and their characterization Journal of Biomedical Materials Research. ,vol. 59, pp. 18- 28 ,(2002) , 10.1002/JBM.1212
H. Dong, A. Bloyce, P. H. Morton, T. Bell, Surface engineering TO improve tribological performance of Ti-6Al-4V Surface Engineering. ,vol. 13, pp. 402- 406 ,(1997) , 10.1179/SUR.1997.13.5.402