Investigation of adsorption-desorption phenomenon by using current fluctuations of amperometric NO 2 gas sensor

作者: Petr Sedlak , Jiri Majzner , Robert Macku , Pavel Skarvada , Vlasta Sedlakova

DOI: 10.1109/ICNF.2015.7288559

关键词:

摘要: Nitrogen dioxide (NO 2 ) is a highly toxic gas harmful to the environment even at low concentrations. To overcome limitations of standard solid NO sensors based on inorganic materials, fully printed sensor with polymer electrolytes (SPE) was developed in Regional Innovation Centre for Electrical engineering Czech Republic. The amperometric semi-planar three-electrode topology (reference, working and counter electrode) electrolyte. This paper focuses adsorption-desorption phenomenon by studying current fluctuations mean value during its exposition concentration cycle. Limits are from 0 6 ppm. Background noise thermal only apparent zero concentration, while, 1/f becomes main component higher

参考文章(28)
Zuzana Hoherčáková, František Opekar, Au/PVC composite—a new material for solid-state gas sensors: Detection of nitrogen dioxide in the air Sensors and Actuators B-chemical. ,vol. 97, pp. 379- 386 ,(2004) , 10.1016/J.SNB.2003.09.016
Chu K. Kuo, James J. Brophy, A Review of Noise Studies in Superionic Electrolytes Technical Report No. 18. ,(1988)
Bernardo Jaduszliwer, Charles M. Klimcak, Sensor for detection of nitrogen dioxide and nitrogen tetroxide ,(1995)
J. Majzner, P. Sedlak, M. Strunc, J. Sikula, Noise in Piezoceramics international conference on noise and fluctuations. ,vol. 922, pp. 347- 352 ,(2007) , 10.1063/1.2759698
Gas sensing by thermoelectric voltage fluctuations in SnO2 nanoparticle films Sensors and Actuators B-chemical. ,vol. 106, pp. 708- 712 ,(2005) , 10.1016/J.SNB.2004.09.021
Petr Sedlak, Jiri Majzner, Josef Sikula, Massimo Macucci, Giovanni Basso, Nyquist Relation and Its Validity for Piezoelectric Ceramics Considering Temperature NOISE AND FLUCTUATIONS: 20th International Conference on Noise and Fluctuations#N#(ICNF‐2009). ,vol. 1129, pp. 141- 144 ,(2009) , 10.1063/1.3140415
Debbie S. Silvester, Recent advances in the use of ionic liquids for electrochemical sensing Analyst. ,vol. 136, pp. 4871- 4882 ,(2011) , 10.1039/C1AN15699C
Marina Santo Zarnik, Vlasta Sedlakova, Darko Belavic, Josef Sikula, Jiri Majzner, Petr Sedlak, Estimation of the long-term stability of piezoresistive LTCC pressure sensors by means of low-frequency noise measurements Sensors and Actuators A-physical. ,vol. 199, pp. 334- 343 ,(2013) , 10.1016/J.SNA.2013.05.030
P. Kuberský, P. Sedlák, A. Hamáček, S. Nešpůrek, T. Kuparowitz, J. Šikula, J. Majzner, V. Sedlaková, L. Grmela, T. Syrový, Quantitative fluctuation-enhanced sensing in amperometric NO2 sensors Chemical Physics. ,vol. 456, pp. 111- 117 ,(2015) , 10.1016/J.CHEMPHYS.2014.10.021
P. Kuberský, T. Syrový, A. Hamáček, S. Nešpůrek, L. Syrová, Towards a fully printed electrochemical NO2 sensor on a flexible substrate using ionic liquid based polymer electrolyte Sensors and Actuators B-chemical. ,vol. 209, pp. 1084- 1090 ,(2015) , 10.1016/J.SNB.2014.12.116