作者: I. J. Marin , M. Poljak , K. Seme , J. Meglic-Volkar , M. Maticic
DOI: 10.1128/JCM.39.2.758-761.2001
关键词:
摘要: Comparative evaluation of the semiautomated COBAS AMPLICOR hepatitis B virus (HBV) MONITOR Test (COBAS-HBV) and manual HBV (AMPLICOR-HBV) on 208 serum samples revealed no significant difference in sensitivities two assays. Twenty tested DNA negative 183 positive by both Three COBAS-HBV only AMPLICOR-HBV only. concentrations determined assays were significantly related (n = 183, r 0.97, P < 0.0001), which indicates that could replace AMPLICOR-HBV. The major inconvenience is required performance appropriate predilutions high-titer order to extend narrow dynamic range assay.