作者: C. X-Z. Zhang , S. I. Kim , I. Hassan
DOI: 10.2514/1.35230
关键词:
摘要: The performance of a louver-cooling scheme on flat plate was analyzed using detached-eddy-simulation turbulence model. It assumed that the tested in wind tunnel with mainstream flow velocity 20 m/s, equivalent to Reynolds number 16,200, based jet diameter. Turbulence closure achieved by realizable k-e-based Solutions two blowing ratios 0.5 and 1 were successfully obtained running parallel 16 nodes computer cluster. flowfields found be highly unsteady oscillatory nature, maximum fluctuation adiabatic effectiveness as high 15% time-averaged value. is shown fluctuations are mainly caused spanwise coolant vortical structures created interaction mainstream.