A clinical study of the human lens with a dynamic light scattering device

作者: Manuel B. Datiles , Rafat R. Ansari , George F. Reed

DOI: 10.1006/EXER.2001.1106

关键词:

摘要: A study was conducted to determine the potential usefulness and repeatability of a new dynamic light scattering (DLS) device for clinical studies of the human lens and early cataract. Studies using the cold cataract model showed this new device to be more sensitive than the Scheimpflug cataract imaging system in detecting the earliest cataractous changes. A miniaturized clinical DLS device developed by NASA using fiber optic probes was mounted on a Keratoscope (Optikon 2000), which has a 3-dimensional aiming system for …

参考文章(23)
Abraham Spector, Suzanne Li, Jesse Sigelman, Age-dependent changes in the molecular size of human lens proteins and their relationship to light scatter. Investigative Ophthalmology & Visual Science. ,vol. 13, pp. 795- 798 ,(1974)
G B Benedek, T Tanaka, Observation of protein diffusivity in intact human and bovine lenses with application to cataract. Investigative Ophthalmology & Visual Science. ,vol. 14, pp. 449- 456 ,(1975)
M Datiles, J H Kinoshita, T S Hu, Reversal of galactose cataract with Sorbinil in rats. Investigative Ophthalmology & Visual Science. ,vol. 24, pp. 640- 644 ,(1983)
J H Kinoshita, T S Hu, L O Merola, T Kuwabara, Prevention and reversal of galactose cataract in rats with topical Sorbinil. Investigative Ophthalmology & Visual Science. ,vol. 25, pp. 603- 605 ,(1984)
Thomas David Duane, William Tasman, Duane's Clinical Ophthalmology ,(1993)
Rafat R. Ansari, Manuel B. Datiles III, James F. King, Doretha Leftwood, Measuring lens opacity: combining quasi-elastic light scattering with Scheimpflug imaging system BiOS '98 International Biomedical Optics Symposium. ,vol. 3246, pp. 35- 42 ,(1998) , 10.1117/12.309433
G. B. Benedek, Theory of Transparency of the Eye Applied Optics. ,vol. 10, pp. 459- 473 ,(1971) , 10.1364/AO.10.000459
M. Van Laethem, B. Babusiaux, A. Neetens, J. Clauwaert, Photon correlation spectroscopy of light scattered by eye lenses in in vivo conditions Biophysical Journal. ,vol. 59, pp. 433- 444 ,(1991) , 10.1016/S0006-3495(91)82237-8
Rafat R. Ansari, Manuel B. Datiles III, James F. King, New clinical instrument for the early detection of cataract using dynamic light scattering and corneal topography BiOS 2000 The International Symposium on Biomedical Optics. ,vol. 3908, pp. 38- 49 ,(2000) , 10.1117/12.387509
R. S. Stock, W. H. Ray, Interpretation of photon correlation spectroscopy data: A comparison of analysis methods Journal of Polymer Science: Polymer Physics Edition. ,vol. 23, pp. 1393- 1447 ,(1985) , 10.1002/POL.1985.180230707