Evaluation of Heat Generation in Unidirectional Versus Oscillatory Modes During K‐Wire Insertion in Bone

作者: Yuanqiang Luo , Lei Chen , Fred T. Finney , Dae Woo Park , Paul G. Talusan

DOI: 10.1002/JOR.24345

关键词:

摘要: … were used to drill five holes under each drilling mode. When a K-wire insertion test failed to penetrate through the bone due to improper techniques or excessive tool wear was observed …

参考文章(20)
Brisman Dl, The effect of speed, pressure, and time on bone temperature during the drilling of implant sites. International Journal of Oral & Maxillofacial Implants. ,vol. 11, pp. 35- ,(1996)
Faruk Karaca, Bunyamin Aksakal, Effects of various drilling parameters on bone during implantology: An in vitro experimental study. Acta of Bioengineering and Biomechanics. ,vol. 15, pp. 25- 32 ,(2013)
Bruce L. Tai, Andrew C. Palmisano, Barry Belmont, Todd A Irwin, James Holmes, Albert J. Shih, Numerical evaluation of sequential bone drilling strategies based on thermal damage Medical Engineering & Physics. ,vol. 37, pp. 855- 861 ,(2015) , 10.1016/J.MEDENGPHY.2015.06.002
JuEun Lee, Yoed Rabin, O. Burak Ozdoganlar, A new thermal model for bone drilling with applications to orthopaedic surgery. Medical Engineering & Physics. ,vol. 33, pp. 1234- 1244 ,(2011) , 10.1016/J.MEDENGPHY.2011.05.014
Stephen A. Sapareto, William C. Dewey, Thermal dose determination in cancer therapy International Journal of Radiation Oncology Biology Physics. ,vol. 10, pp. 787- 800 ,(1984) , 10.1016/0360-3016(84)90379-1
Larry S. Nichter, Spencer Richlin, Patricia M. Navarrette, Kambiz Kosari, The biomechanical efficacy of an oscillating K-wire driver. Annals of Plastic Surgery. ,vol. 29, pp. 289- 292 ,(1992) , 10.1097/00000637-199210000-00001
M.T Hillery, I Shuaib, Temperature effects in the drilling of human and bovine bone Journal of Materials Processing Technology. ,vol. 92, pp. 302- 308 ,(1999) , 10.1016/S0924-0136(99)00155-7
JuEun Lee, O. Burak Ozdoganlar, Yoed Rabin, An experimental investigation on thermal exposure during bone drilling Medical Engineering & Physics. ,vol. 34, pp. 1510- 1520 ,(2012) , 10.1016/J.MEDENGPHY.2012.03.002
A. KHANNA, S. J. PLESSAS, P. BARRETT, L. C. BAINBRIDGE, The Thermal Effects of Kirschner Wire Fixation on Small Bones Journal of Hand Surgery (European Volume). ,vol. 24, pp. 355- 357 ,(1999) , 10.1054/JHSB.1998.0055
Rupesh Kumar Pandey, S.S. Panda, Drilling of bone: A comprehensive review. Journal of clinical orthopaedics and trauma. ,vol. 4, pp. 15- 30 ,(2013) , 10.1016/J.JCOT.2013.01.002