A comparison between track-structure, condensed-history Monte Carlo simulations and MIRD cellular S-values.

作者: M A Tajik-Mansoury , H Rajabi , H Mozdarani

DOI: 10.1088/1361-6560/62/5/N90

关键词:

摘要: The S-value is a standard measure in cellular dosimetry. S-values are calculated by applying analytical methods or Monte Carlo simulation. In simulation, particles either tracked individually event-by-event close events condensed and processed collectively different steps. Both of these have been employed for estimation S-values, but there no consistency between the published results. present paper, we used Geant4-DNA track-structure physics model as reference to estimate S-values. We compared results with corresponding values obtained from following three condensed-history models Geant4: Penelope, Livermore standard. geometry source were exactly same all simulations. utilized mono-energetic electrons an initial kinetic energy range 1-700 keV radiation. also our MIRD first drew overall comparison data series then dependence on size scoring compartments. indicated very good linear correlation (R 2  >  91%) small bias (3%) model. simulation was considerable (-8%). However, point-by-point revealed differences up 28% MC codes self-absorption 10-50 keV range. For cross-absorption difference 34%. this range, 68%. Our findings suggest that consistency/inconsistency simulations depends volumes, particles, step-size electron tracking cutoff codes.

参考文章(44)
Martin Šefl, Sébastien Incerti, George Papamichael, Dimitris Emfietzoglou, Calculation of cellular S-values using Geant4-DNA: The effect of cell geometry. Applied Radiation and Isotopes. ,vol. 104, pp. 113- 123 ,(2015) , 10.1016/J.APRADISO.2015.06.027
S. James Adelstein, Amin I. Kassis, Radiobiologic Principles in Radionuclide Therapy The Journal of Nuclear Medicine. ,vol. 46, ,(2005)
Wei Bo Li, Werner Friedland, Ekkehard Pomplun, Peter Jacob, Herwig G. Paretzke, Michael Lassmann, Christoph Reiners, Track Structures and Dose Distributions from Decays of 131I and 125I in and around Water Spheres Simulating Micrometastases of Differentiated Thyroid Cancer Radiation Research. ,vol. 156, pp. 419- 429 ,(2001) , 10.1667/0033-7587(2001)156[0419:TSADDF]2.0.CO;2
I. Kawrakow, Alex F. Bielajew, On the condensed history technique for electron transport Nuclear Instruments & Methods in Physics Research Section B-beam Interactions With Materials and Atoms. ,vol. 142, pp. 253- 280 ,(1998) , 10.1016/S0168-583X(98)00274-2
D. Emfietzoglou, C. Bousis, C. Hindorf, A. Fotopoulos, A. Pathak, K. Kostarelos, A Monte Carlo study of energy deposition at the sub-cellular level for application to targeted radionuclide therapy with low-energy electron emitters Nuclear Instruments & Methods in Physics Research Section B-beam Interactions With Materials and Atoms. ,vol. 256, pp. 547- 553 ,(2007) , 10.1016/J.NIMB.2006.12.055
A. A. Parach, H. Rajabi, A comparison between GATE4 results and MCNP4B published data for internal radiation dosimetry. Nuklearmedizin-nuclear Medicine. ,vol. 50, pp. 122- 133 ,(2011) , 10.3413/NUKMED-0363-10-10
A. E. Nahum, Condensed-history Monte-Carlo simulation for charged particles: what can it do for us? Radiation and Environmental Biophysics. ,vol. 38, pp. 163- 173 ,(1999) , 10.1007/S004110050152
R. Freudenberg, J. Kotzerke, Cellular dosimetry using the Geant4 Monte Carlo toolkit. The Journal of Nuclear Medicine. ,vol. 51, pp. 1488- 1489 ,(2010) , 10.2967/JNUMED.110.078832
C. Champion, S. Incerti, Y. Perrot, R. Delorme, M.C. Bordage, M. Bardiès, B. Mascialino, H.N. Tran, V. Ivanchenko, M. Bernal, Z. Francis, J.-E. Groetz, M. Fromm, L. Campos, Dose point kernels in liquid water: An intra-comparison between GEANT4-DNA and a variety of Monte Carlo codes Applied Radiation and Isotopes. ,vol. 83, pp. 137- 141 ,(2014) , 10.1016/J.APRADISO.2013.01.037