Calculating photon beam characteristics with Monte Carlo techniques

作者: W. van der Zee , J. Welleweerd

DOI: 10.1118/1.598694

关键词:

摘要: This study describes the results from a simulation of 10 MV photon beam medical linac using BEAM code. To check quality generated beam, characteristics this (depth dose curve, cross profiles, and output factors) have been calculated compared to measured data. By splitting up radiation head in two parts, target section collimator calculation times were long, but acceptable when aiming at phase space files containing some 5 million particles. Given number particles evaluated, accuracy all data was around 2%. Analysis for different field size supports previous studies about contaminant sources scattered beams linacs. The total scatter factor Scp as well Sc within 2% measurements. Also, ratio between reference point full situation no-scatter has correctly. All depth curves profiles also correctly, although with only moderate statistics. Improvements are possible by increasing simulations (up 50 largest size) least 4-8 times, will increase same factor. Nevertheless, method proved itself reliable. Still, should be improved 1% or better. is necessary we plan use Monte Carlo benchmark three-dimensional radiotherapy planning systems. subsequently each simulation, achieved. easy way files, which already recycled ten reused (this study) 40 more not work, it introduces artifacts, especially profiles.

参考文章(30)
Martin J. Butson, Tony P. Y. Wong, Andy Law, Maria Law, Jagdish N. Mathur, Peter E. Metcalfe, Magnetic repulsion of linear accelerator contaminates Medical Physics. ,vol. 23, pp. 953- 955 ,(1996) , 10.1118/1.597818
Steve B. Jiang, Komanduri M. Ayyangar, On compensator design for photon beam intensity-modulated conformal therapy. Medical Physics. ,vol. 25, pp. 668- 675 ,(1998) , 10.1118/1.598250
J.Van Dyk, R.B. Barnett, J.E. Cygler, P.C. Shragge, Commissioning and quality assurance of treatment planning computers International Journal of Radiation Oncology Biology Physics. ,vol. 26, pp. 261- 273 ,(1993) , 10.1016/0360-3016(93)90206-B
J.J.M. van Gasteren, S. Heukelom, H.J. van Kleffens, R. van der Laarse, J.L.M. Venselaar, C.F. Westermann, The determination of phantom and collimator scatter components of the output of megavoltage photon beams: measurement of the collimator scatter part with a beam-coaxial narrow cylindrical phantom. Radiotherapy and Oncology. ,vol. 20, pp. 250- 257 ,(1991) , 10.1016/0167-8140(91)90124-Y
D. M. J. Lovelock, C. S. Chui, R. Mohan, A Monte Carlo model of photon beams used in radiation therapy Medical Physics. ,vol. 22, pp. 1387- 1394 ,(1995) , 10.1118/1.597620
M Udale-Smith, Monte Carlo calculations of electron beam parameters for three Philips linear accelerators Physics in Medicine and Biology. ,vol. 37, pp. 85- 105 ,(1992) , 10.1088/0031-9155/37/1/006
C. X. Yu, T. R. Mackie, J. W. Wong, Photon dose calculation incorporating explicit electron transport Medical Physics. ,vol. 22, pp. 1157- 1165 ,(1995) , 10.1118/1.597611
Christoph Börgers, Complexity of Monte Carlo and deterministic dose-calculation methods Physics in Medicine and Biology. ,vol. 43, pp. 517- 528 ,(1998) , 10.1088/0031-9155/43/3/004
Bruce R. Thomadsen, Shrikant S. Kubsad, Bhudatt R. Paliwal, Siamak Shahabi, T. Rockwell Mackie, On the cause of the variation in tissue‐maximum ratio values with source‐to‐detector distance Medical Physics. ,vol. 20, pp. 723- 727 ,(1993) , 10.1118/1.597022