Cooling load and coefficient of performance optimizations for real air-refrigerators

作者: Youming Tu , Lingen Chen , Fengrui Sun , Chih Wu

DOI: 10.1016/J.APENERGY.2006.03.003

关键词:

摘要: Based on a simple irreversible variable-temperature heat reservoir air (Brayton) refrigeration cycle model, performance analysis and optimization of real refrigerator is carried out using finite-time thermodynamics. To maximize the cooling load coefficient (COP) cycle, allocation fixed total heat-exchanger inventory thermal-capacity rate matching between working fluid reservoirs are optimized, respectively. The influences pressure ratio, inventory, efficiencies compressor expander, thermal capacity ratio rates shown by numerical examples. results obtained provide guidances for design practical air-refrigeration plants.

参考文章(23)
J. A. McCormick, W. L. Swift, H. Sixsmith, Progress on the Development of Miniature Turbomachines for Low-Capacity Reverse-Brayton Cryocoolers Springer, Boston, MA. pp. 475- 483 ,(1997) , 10.1007/978-1-4615-5869-9_55
L. Chen, F. Sun, C. Wu, Finite-time thermodynamic performance of an isentropic closed regenerated Brayton refrigeration cycle International Journal of Energy and Environment. ,vol. 4, ,(1997)
R Stephen Berry, Vladimir A Kazakov, S. Sieniutycz, Z Szwast, Anatoly M Tsirlin, Thermodynamic Optimization of Finite-Time Processes ,(2000)
Jun Luo, Lingen Chen, Fengrui Sun, Chih Wu, Optimum Allocation of Heat Exchanger Inventory of Irreversible Air Refrigeration Cycles Physica Scripta. ,vol. 65, pp. 410- 415 ,(2002) , 10.1238/PHYSICA.REGULAR.065A00410
Shengbing Zhou, Lingen Chen, Fengrui Sun, Chih Wu, Theoretical optimization of a regenerated air refrigerator Journal of Physics D. ,vol. 36, pp. 2304- 2311 ,(2003) , 10.1088/0022-3727/36/18/020
Chih Wu, Lingen Chen, Fengrui Sun, Optimisation of steady flow refrigeration cycles International journal of ambient energy. ,vol. 17, pp. 199- 206 ,(1996) , 10.1080/01430750.1996.9675244
Shengbing Zhou, Lingen Chen, Fengrui Sun, Chih Wu, Cooling Load Density Optimization of an Irreversible Simple Brayton Refrigerator Open Systems & Information Dynamics. ,vol. 09, pp. 325- 337 ,(2002) , 10.1023/A:1021854217387
S. A. Klein, D. T. Reindl, The Relationship of Optimum Heat Exchanger Allocation and Minimum Entropy Generation Rate for Refrigeration Cycles Journal of Energy Resources Technology-transactions of The Asme. ,vol. 120, pp. 172- 178 ,(1998) , 10.1115/1.2795030
Shengbing Zhou, Lingen Chen, Fengrui Sun, Chih Wu, Cooling-load density optimization for a regenerated air refrigerator Applied Energy. ,vol. 78, pp. 315- 328 ,(2004) , 10.1016/J.APENERGY.2003.08.008
Lingen Chen, Shengbing Zhou, Fengrui Sun, Chih Wu, Performance of heat-transfer irreversible regenerated Brayton refrigerators Journal of Physics D. ,vol. 34, pp. 830- 837 ,(2001) , 10.1088/0022-3727/34/5/322