Stator harmonic current suppression for DFIG wind power system under distorted grid voltage

作者: Wenjie Chen , Jun Xu , Nan Zhu , Changjin Liu , Min Chen

DOI: 10.1109/PEDG.2012.6254019

关键词:

摘要: Effects of lower order harmonic grid voltage on the stator current Doubly Fed Induction Generator (DFIG) are investigated. A control method for DFIG wind power system is presented to suppress effects current. The proposed scheme analyzed using transfer function. performance verified by both simulation and experiment a prototype.

参考文章(14)
S. Muller, M. Deicke, R.W. De Doncker, Doubly fed induction generator systems for wind turbines IEEE Industry Applications Magazine. ,vol. 8, pp. 26- 33 ,(2002) , 10.1109/2943.999610
Hailiang Xu, Jiabing Hu, Yikang He, Operation of Wind-Turbine-Driven DFIG Systems Under Distorted Grid Voltage Conditions: Analysis and Experimental Validations IEEE Transactions on Power Electronics. ,vol. 27, pp. 2354- 2366 ,(2012) , 10.1109/TPEL.2011.2174255
Changjin Liu, Frede Blaabjerg, Wenjie Chen, Dehong Xu, Stator Current Harmonic Control With Resonant Controller for Doubly Fed Induction Generator IEEE Transactions on Power Electronics. ,vol. 27, pp. 3207- 3220 ,(2012) , 10.1109/TPEL.2011.2179561
C. J. Ramos, A. P. Martins, A. S. Carvalho, Rotor Current Controller with Voltage Harmonics Compensation for a DFIG Operating under Unbalanced and Distorted Stator Voltage conference of the industrial electronics society. pp. 1287- 1292 ,(2007) , 10.1109/IECON.2007.4459938
Lie Xu, Yi Wang, Dynamic Modeling and Control of DFIG-Based Wind Turbines Under Unbalanced Network Conditions IEEE Transactions on Power Systems. ,vol. 22, pp. 314- 323 ,(2007) , 10.1109/TPWRS.2006.889113
M. Kiani, Wei-Jen Lee, Effects of Voltage Unbalance and System Harmonics on the Performance of Doubly Fed Induction Wind Generators IEEE Transactions on Industry Applications. ,vol. 46, pp. 562- 568 ,(2010) , 10.1109/TIA.2010.2041087
A. Gaillard, P. Poure, S. Saadate, Active filtering capability of WECS with DFIG for grid power quality improvement international symposium on industrial electronics. pp. 2365- 2370 ,(2008) , 10.1109/ISIE.2008.4676984
Jiabing Hu, Heng Nian, Hailiang Xu, Yikang He, Dynamic Modeling and Improved Control of DFIG Under Distorted Grid Voltage Conditions IEEE Transactions on Energy Conversion. ,vol. 26, pp. 163- 175 ,(2011) , 10.1109/TEC.2010.2071875
M. Liserre, R. Teodorescu, F. Blaabjerg, Multiple harmonics control for three-phase grid converter systems with the use of PI-RES current controller in a rotating frame IEEE Transactions on Power Electronics. ,vol. 21, pp. 836- 841 ,(2006) , 10.1109/TPEL.2006.875566
JesÚs LÓpez, Pablo Sanchis, Xavier Roboam, Luis Marroyo, Dynamic Behavior of the Doubly Fed Induction Generator During Three-Phase Voltage Dips IEEE Transactions on Energy Conversion. ,vol. 22, pp. 709- 717 ,(2007) , 10.1109/TEC.2006.878241