Mechanical ventilation with positive end-expiratory pressure in critically ill patients: comparison of CW-Doppler ultrasound cardiac output monitoring (USCOM) and thermodilution (PiCCO).

作者: Sophia Horster , Hans Joachim Stemmler , Jakob Sparrer , Johanna Tischer , Andreas Hausmann

DOI: 10.1080/AC.67.2.2154208

关键词:

摘要: Background Aggressive mechanical ventilation can markedly and unpredictably aff ect cardiac function. The fall in output (CO) is due to a reduction left ventricular stroke volume (SV). aim of the present pilot study was assess eff ects diff erent positive end-expiratory pressure (PEEP) levels on circulatory function compare them with continuous wave (CW)-Doppler ultrasound monitoring (USCOM) thermodilution-based haemodynamic system (PiCCO).Methods Twenty mechanically ventilated (PEEP ≤10 mbar) adult patients (female n = 6, male 14, mean age 62 years, SAPS II-score 48.5), majority pneumonia septic shock) were followed USCOM PiCCO at stepwise increased PEEP-levels from 0-10 mbar (1 steps). changes CO/SV recorded.Results With both methods, an increase PEEP resulted decrease SV CO. Although absolute consistently higher by USCOM, parameters qual...

参考文章(34)
H. L. A. Van Den Oever, E. J. Murphy, G. A. Christie-Taylor, USCOM (Ultrasonic Cardiac Output Monitors) lacks agreement with thermodilution cardiac output and transoesophageal echocardiography valve measurements. Anaesthesia and Intensive Care. ,vol. 35, pp. 903- 910 ,(2007) , 10.1177/0310057X0703500608
Priya Nair, Janet S Chan, Davendra Segara, Measurement of cardiac output with a non-invasive continuous wave Doppler device versus the pulmonary artery catheter: a comparative study Critical Care and Resuscitation. ,vol. 8, pp. 309- ,(2006)
Lester A. H. Critchley, Julian A. J. H. Critchley, A meta-analysis of studies using bias and precision statistics to compare cardiac output measurement techniques. Journal of Clinical Monitoring and Computing. ,vol. 15, pp. 85- 91 ,(1999) , 10.1023/A:1009982611386
Fuat H. Saner, Steven W. M. Olde Damink, Goran Pavlakovic, Maartje A. J. van den Broek, Peter-Michael Rath, Georgios C. Sotiropoulos, Arnold Radtke, Ali Canbay, Andreas Paul, Silvio Nadalin, Massimo Malagó, Christoph E. Broelsch, Pulmonary and blood stream infections in adult living donor and cadaveric liver transplant patients. Transplantation. ,vol. 85, pp. 1564- 1568 ,(2008) , 10.1097/TP.0B013E31816F61A6
Bai-Chuan Su, Chih-Chung Lin, Chih-Wen Su, Yu-Ling Hui, Yung-Fong Tsai, Ming-Wen Yang, Ping-Wing Lui, Ultrasonic Cardiac Output Monitor Provides Accurate Measurement of Cardiac Output in Recipients After Liver Transplantation Acta Anaesthesiologica Taiwanica. ,vol. 46, pp. 171- 177 ,(2008) , 10.1016/S1875-4597(09)60005-9
Jean-Marie Schmitt, Antoine Vieillard-Baron, Roch Augarde, Sebastien Prin, Bernard Page, François Jardin, Positive end-expiratory pressure titration in acute respiratory distress syndrome patients: Impact on right ventricular outflow impedance evaluated by pulmonary artery Doppler flow velocity measurements Critical Care Medicine. ,vol. 29, pp. 1154- 1158 ,(2001) , 10.1097/00003246-200106000-00012
Rob Phillips, Peter Lichtenthal, Julie Sloniger, Darryl Burstow, Malcolm West, Jack Copeland, None, Noninvasive cardiac output measurement in heart failure subjects on circulatory support Anesthesia & Analgesia. ,vol. 108, pp. 881- 886 ,(2009) , 10.1213/ANE.0B013E318193174B
Lai-Sze Grace Wong, Boon-Hun Yong, Karl Kang Young, Lee-Sung Lau, King-Lik Cheng, Jeff Siu-Fan Man, Michael G. Irwin, Comparison of the USCOM ultrasound cardiac output monitor with pulmonary artery catheter thermodilution in patients undergoing liver transplantation Liver Transplantation. ,vol. 14, pp. 1038- 1043 ,(2008) , 10.1002/LT.21483
H. Bryant Nguyen, Daryl P. Banta, Gail Stewart, Tommy Kim, Ramesh Bansal, James Anholm, William A. Wittlake, Stephen W. Corbett, Cardiac index measurements by transcutaneous Doppler ultrasound and transthoracic echocardiography in adult and pediatric emergency patients. Journal of Clinical Monitoring and Computing. ,vol. 24, pp. 237- 247 ,(2010) , 10.1007/S10877-010-9240-6
Bai-Chuan Su, Huang-Ping Yu, Ming-Wen Yang, Chih-Chung Lin, Ming-Chang Kao, Chia-Hung Chang, Wei-Chen Lee, Reliability of a new ultrasonic cardiac output monitor in recipients of living donor liver transplantation Liver Transplantation. ,vol. 14, pp. 1029- 1037 ,(2008) , 10.1002/LT.21461