Maximal myocardial perfusion as a measure of the functional significance of coronary artery disease

作者: Nico H. J. Pijls , Joost den Arend , Karel van Leeuwen , Truus Pijnenburg , Evert Lamfers

DOI: 10.1007/978-94-011-1854-5_12

关键词:

摘要: Over the last decade it has become more and obvious that, besides anatomic information about severity of coronary artery stenoses, myocardial blood flow is necessary to completely understand functional significance these lesions. Methods measure in clinical practice, however, have been disappointing until now.

参考文章(36)
WILHELM RUTISHAUSER, GIORGIO NOSEDA, WULF-DIRK BUSSMANN, BRUNO PRETER, BLOOD FLOW MEASUREMENT THROUGH SINGLE CORONARY ARTERIES BY ROENTGEN DENSITOMETRY American Journal of Roentgenology. ,vol. 109, pp. 21- 24 ,(1970) , 10.2214/AJR.109.1.21
E R Bates, F M Aueron, V Legrand, M T LeFree, G B Mancini, J M Hodgson, R A Vogel, Comparative long-term effects of coronary artery bypass graft surgery and percutaneous transluminal coronary angioplasty on regional coronary flow reserve. Circulation. ,vol. 72, pp. 833- 839 ,(1985) , 10.1161/01.CIR.72.4.833
Masakiyo Nobuyoshi, Takeshi Kimura, Hideyuki Nosaka, Sokei Mioka, Katsumi Ueno, Hiroatsu Yokoi, Naoya Hamasaki, Hisanori Horiuchi, Hiroto Ohishi, Restenosis After Successful Percutaneous Transluminal Coronary Angioplasty: Serial Angiographic Follow-Up of 229 Patients Journal of the American College of Cardiology. ,vol. 12, pp. 616- 623 ,(1988) , 10.1016/S0735-1097(88)80046-9
Lloyd W. Klein, Jai B. Agarwal, Ricky M. Schneider, George Hermann, William S. Weintraub, Richard H. Helfant, Effects of previous myocardial infarction on measurements of reactive hyperemia and the coronary vascular reserve Journal of the American College of Cardiology. ,vol. 8, pp. 357- 363 ,(1986) , 10.1016/S0735-1097(86)80051-1
Glen W. Hamilton, Gene B. Trobaugh, James L. Ritchie, K. Lance Gould, Timothy A. DeRouen, David L. Williams, Myocardial imaging with 201Thallium: An analysis of clinical usefulness based on bayes' theorem Seminars in Nuclear Medicine. ,vol. 8, pp. 358- 364 ,(1978) , 10.1016/S0001-2998(78)80021-X
R A Vogel, The radiographic assessment of coronary blood flow parameters. Circulation. ,vol. 72, pp. 460- 465 ,(1985) , 10.1161/01.CIR.72.3.460
Martin T. Rothman, Donald S. Baim, John B. Simpson, Donald C. Harrison, Coronary hemodynamics during percutaneous transluminal coronary angioplasty American Journal of Cardiology. ,vol. 49, pp. 1615- 1622 ,(1982) , 10.1016/0002-9149(82)90236-3
Nico H. J. Pijls, Gerard J. H. Uijen, Albert Hoevelaken, Truus Pijnenburg, Karel L. van Leeuwen, Jules H. Fast, Hans S. Bos, Wim R. Aengevaeren, Tjeerd van der Werf, Mean transit time for videodensitometric assessment of myocardial perfusion and the concept of maximal flow ratio: a validation study in the intact dog and a pilot study in man. International Journal of Cardiac Imaging. ,vol. 5, pp. 191- 202 ,(1990) , 10.1007/BF01833988