Novel application for ion mobility spectrometry: diagnosing vaginal infections through measurement of biogenic amines

作者: Zeev Karpas , Walter Chaim , Rachel Gdalevsky , Boris Tilman , Avi Lorber

DOI: 10.1016/S0003-2670(02)01007-3

关键词:

摘要: Abstract A method for diagnosis of bacterial vaginosis (BV) and other vaginal infections, based on measurement biogenic amines present in a sample fluid by ion mobility spectrometry (IMS) was developed. Sample introduction is through two step procedure: addition alkaline solution to release the volatile followed heating acid emanation semi-volatile amines. Addition n-nonylamine vapors carrier gas stream helps control ionization processes enhances selective response amines, even complex environment biological matrices. software package developed acquisition, storage processing spectra providing table rules. We report results from testing 210 samples discharge that were diagnosed gynecologist according widely used reference (Amsel test) new IMS method. The rapid (less than 2 min per sample), has high sensitivity (few False Negatives) specificity Positives) with an accuracy >95% BV. use this can reduce incidence misdiagnosis, particularly when trichomoniasis confused vaginosis.

参考文章(15)
J M Brand, R P Galask, Trimethylamine: the substance mainly responsible for the fishy odor often associated with bacterial vaginosis. Obstetrics & Gynecology. ,vol. 68, pp. 682- 685 ,(1986)
Tormod Næs, Tom Fearn, Tomas Isaksson, Tony Davies, A user-friendly guide to multivariate calibration and classification NIR Publications: Chichester UK. (2002). ,(2017) , 10.1255/978-1-906715-25-0
Gerard A. Cangelosi, Diana K. Sheiness, Theresa B. Britschgi, Nucleic acid probes useful for detecting microorganisms associated with vaginal infections ,(1995)
Richard Amsel, Patricia A. Totten, Carol A. Spiegel, Kirk C.S. Chen, David Eschenbach, King K. Holmes, Nonspecific vaginitis The American Journal of Medicine. ,vol. 74, pp. 14- 22 ,(1983) , 10.1016/0002-9343(83)91112-9
Clive Solomons, David Bar-Or, Method for the very rapid detection of polyamines ,(1991)
R P Nugent, M A Krohn, S L Hillier, Reliability of diagnosing bacterial vaginosis is improved by a standardized method of gram stain interpretation. Journal of Clinical Microbiology. ,vol. 29, pp. 297- 301 ,(1991) , 10.1128/JCM.29.2.297-301.1991
K. C. S. Chen, R. Amsel, D. A. Eschenbach, K. K. Holmes, Biochemical Diagnosis of Vaginitis: Determination of Diamines in Vaginal Fluid The Journal of Infectious Diseases. ,vol. 145, pp. 337- 345 ,(1982) , 10.1093/INFDIS/145.3.337
Zeev Karpas, Zvi Berant, Robert M. Stimac, An ion mobility spectrometry/mass spectrometry (IMS/MS) study of the site of protonation in anilines Structural Chemistry. ,vol. 1, pp. 201- 204 ,(1990) , 10.1007/BF00674262
Zeev. Karpas, Ion mobility spectrometry of aliphatic and aromatic amines Analytical Chemistry. ,vol. 61, pp. 684- 689 ,(1989) , 10.1021/AC00182A009
Clarke X Xu, Sayed AM Marzouk, Vasile V Cosofret, Richard P Buck, Michael R Neuman, Robert H Sprinkle, Development of a diamine biosensor. Talanta. ,vol. 44, pp. 1625- 1632 ,(1997) , 10.1016/S0039-9140(97)00067-2