作者: D.S. Vilchis-Rodriguez , Y. Wei , N. Sarma , S. Djuroviü , A.C. Smith
DOI: 10.1049/CP.2016.0368
关键词:
摘要: This paper investigates the torque and vibration signal spectra of wound rotor induction machines when subjected to different levels electrical unbalance. A harmonic machine model numerical study is first performed identify electromagnetic spectral components related operation without or with Once understanding correlation between operating conditions content established, a series laboratory tests are conducted evaluate manifestation detectability electromagnetically induced matching identified disturbance frequencies in study. The magnitude unbalance signature assessed for range measurements taken on two designs.