On the Frequency Dependence of Attenuation in Normal and Fatty Liver

作者: P.A. Narayana , J. Ophir

DOI: 10.1109/T-SU.1983.31444

关键词:

摘要: Abstruct-The frequency dependence of the attenuation has been investigated in normal and fatty liver samples vitro. It was observed that exhibited essentially a linear dependent attenuation, while livers power law dependence, where exponent n between 1.25-1.4. In order to explain this nonlinear behavior, modeled as consisting tissue which is infiltrated by large number tiny fat globules are 4-10 size occasionally coalesce 100 p, thus act Rayleigh scatterers diagnostic wavelength range. The addition these consistent with clinical observation increased echogenicity livers. Based on physical description, absorption term, fourthader scattering term. This model predicts quantity (n - l) proportional fractional contribution total attenuation. For due scatter amounts 8-13 percent, compared 21 percent for

参考文章(19)
K. A. Dines, A. C. Kak, Ultrasonic attenuation tomography of soft tissues. Ultrasonic Imaging. ,vol. 1, pp. 16- 33 ,(1979) , 10.1177/016173467900100102
P.A. Narayana, J. Ophir, On the validity of the linear approximation in the parametric measurement of attenuation in tissues Ultrasound in Medicine and Biology. ,vol. 9, pp. 357- 361 ,(1983) , 10.1016/0301-5629(83)90088-1
J.C. Bamber, C.R. Hill, J.A. King, Acoustic properties of normal and cancerous human liver—II Dependence on tissue structure Ultrasound in Medicine and Biology. ,vol. 7, pp. 135- 144 ,(1981) , 10.1016/0301-5629(81)90002-8
Jonathan Ophir, Paul Jaeger, Spectral shifts of ultrasonic propagation through media with nonlinear dispersive attenuation Ultrasonic Imaging. ,vol. 4, pp. 282- 289 ,(1982) , 10.1177/016173468200400304
M. Fink, F. Hottier, J.F. Cardoso, Ultrasonic Signal Processing for in Vivo Attenuation Measurement: Short Time Fourier Analysis Ultrasonic Imaging. ,vol. 5, pp. 117- 135 ,(1983) , 10.1177/016173468300500202
J.C. Bamber, C.R. Hill, ACOUSTIC PROPERTIES OF NORMAL AND CANCEROUS HUMAN LIVER---I. DEPENDENCE ON PATHOLOGICAL CONDITION Ultrasound in Medicine and Biology. ,vol. 7, pp. 121- 133 ,(1981) , 10.1016/0301-5629(81)90001-6
Avinash C. Kak, Kris A. Dines, Signal Processing of Broadband Pulsed Ultrasound: Measurement of Attenuation of Soft Biological Tissues IEEE Transactions on Biomedical Engineering. ,vol. BME-25, pp. 321- 344 ,(1978) , 10.1109/TBME.1978.326259
R. Kuc, M. Schwartz, L.V. Micsky, Parametric Estimation of the Acoustic Attenuation Coefficient Slope for Soft Tissue internaltional ultrasonics symposium. pp. 44- 47 ,(1976) , 10.1109/ULTSYM.1976.196626
H. Pauly, H. P. Schwan, Mechanism of Absorption of Ultrasound in Liver Tissue The Journal of the Acoustical Society of America. ,vol. 50, pp. 692- 699 ,(1971) , 10.1121/1.1912685