Surgical Technique: Static Intramedullary Nailing of the Femur and Tibia Without Intraoperative Fluoroscopy

作者: Neil J. White , Anthony T. Sorkin , Geoffrey Konopka , Todd O. McKinley

DOI: 10.1007/S11999-011-1829-7

关键词:

摘要: Background On a recent mission directed at definitive care for victims of the Haitian earthquake, orthopaedic team developed technique freehand distal locking femoral and tibial nails without intraoperative fluoroscopy or proximally mounted targeting jigs.

参考文章(14)
Huckstep Rl, Proceedings: An intramedullary nail for rigid fixation and compression of fractures of the femur. Journal of Bone and Joint Surgery-british Volume. ,vol. 57, pp. 253- 253 ,(1975)
Dinshaw Pardiwala, Vidyanand Prabhu, Gaffar Dudhniwala, Ravindra Katre, The AO distal locking aiming device An evaluation of efficacy and learning curve Injury-international Journal of The Care of The Injured. ,vol. 32, pp. 713- 718 ,(2001) , 10.1016/S0020-1383(01)00100-0
R J Brumback, J P Reilly, A Poka, R P Lakatos, G H Bathon, A R Burgess, Intramedullary nailing of femoral shaft fractures. Part I: Decision-making errors with interlocking fixation. Journal of Bone and Joint Surgery, American Volume. ,vol. 70, pp. 1441- 1452 ,(1988) , 10.2106/00004623-198870100-00002
Robert J. Brumback, The rationales of interlocking nailing of the femur, tibia, and humerus : an overview Clinical Orthopaedics and Related Research. ,vol. 324, pp. 292- 320 ,(1996) , 10.1097/00003086-199603000-00036
S Malek, R Phillips, A Mohsen, W Viant, M Bielby, K Sherman, Computer assisted orthopaedic surgical system for insertion of distal locking screws in intra-medullary nails: a valid and reliable navigation system The International Journal of Medical Robotics and Computer Assisted Surgery. ,vol. 1, pp. 34- 44 ,(2005) , 10.1002/RCS.54
C. Krettek, B. Könemann, T. Miclau, R. Kölbli, T. Machreich, A. Kromm, H. Tscherne, A new mechanical aiming device for the placement of distal interlocking screws in femoral nails Archives of Orthopaedic and Trauma Surgery. ,vol. 117, pp. 147- 152 ,(1998) , 10.1007/S004020050215
Lewis G. Zirkle, David Shearer, SIGN Technique for Retrograde and Antegrade Approaches to Femur Techniques in Orthopaedics. ,vol. 24, pp. 247- 252 ,(2009) , 10.1097/BTO.0B013E3181C3E617
George Anastopoulos, Panagiotis G. Ntagiopoulos, Dionisios Chissas, Athanasios Papaeliou, Antonios Asimakopoulos, Distal locking of tibial nails : a new device to reduce radiation exposure. Clinical Orthopaedics and Related Research. ,vol. 466, pp. 216- 220 ,(2008) , 10.1007/S11999-007-0036-Z
JAMES A. GOULET, FRANK LONDY, CHARLES L. SALTZMAN, LARRY S. MATTHEWS, Interlocking intramedullary nails. An improved method of screw placement combining image intensification and laser light. Clinical Orthopaedics and Related Research. ,vol. 281, pp. 199- 203 ,(1992) , 10.1097/00003086-199208000-00033
Christian Krettek, Bernd K??nemann, Theodore Miclau, Reto K??lbli, Thomas Machreich, Harald Tscherne, A mechanical distal aiming device for distal locking in femoral nails. Clinical Orthopaedics and Related Research. ,vol. 364, pp. 267- 275 ,(1999) , 10.1097/00003086-199907000-00033