Design for manufacturing of custom-made femoral stem using CT data and rapid prototyping technology

作者: Farid Abbaszadeh , Sadegh Rahmati , Hossein Kheirollahi , Farzam Farahmand , None

DOI: 10.1504/IJRAPIDM.2011.040690

关键词:

摘要: Rapid prototyping (RP) applications have an increasing trend, making the future of RP more and promising. These may include design, development, manufacture medical devices instrumentation, as well prosthesis anatomical modelling, surgical planning fabrication. This paper provides a new methodology for design custom-made femoral stem, providing high accuracy canal reconstruction via 3D modelling stem with optimal fill fit. The result this is optimised load transfer, minimum micromotion, increase in initial stability extended durability. In addition to

参考文章(35)
Michael Mont, S. K. Mathur, J. W. McCutchen, Intraoperative custom press-fit and standard press-fit femoral components in total hip arthroplasty. A comparison of surgery, charges, and early complications. American journal of orthopedics. ,vol. 25, pp. 486- 491 ,(1996)
Michel P. Philippe, Elvira Martin, Jacques Hummer, Gérard Gacon, Alain Dambreville, André Ray, The ESOP-HA modular cementless femoral stem: a study of the results of 165 hip arthroplasties with a minimum of 10-year follow-up European Journal of Orthopaedic Surgery and Traumatology. ,vol. 15, pp. 275- 285 ,(2005) , 10.1007/S00590-005-0002-Y
Ola L. A. Harrysson, Denis R. Cormier, Direct Fabrication of Custom Orthopedic Implants Using Electron Beam Melting Technology John Wiley & Sons, Ltd. pp. 191- 206 ,(2006) , 10.1002/0470033983.CH9
Ellen Dhoore, Software for Medical Data Transfer John Wiley & Sons, Ltd. pp. 79- 104 ,(2006) , 10.1002/0470033983.CH5
Sekou Singare, Liu Yaxiong, Li Dichen, Lu Bingheng, He Sanhu, Li Gang, Fabrication of customised maxillo‐facial prosthesis using computer‐aided design and rapid prototyping techniques Rapid Prototyping Journal. ,vol. 12, pp. 206- 213 ,(2006) , 10.1108/13552540610682714
L.C. Hieu, N. Zlatov, J. Vander Sloten, E. Bohez, L. Khanh, P.H. Binh, P. Oris, Y. Toshev, MEDICAL RAPID PROTOTYPING APPLICATIONS AND METHODS Assembly Automation. ,vol. 25, pp. 284- 292 ,(2005) , 10.1108/01445150510626415
Akihiko Bo, Shinichi Imura, Hironori Omori, Yasuhiro Okumura, Masao Ando, Hisatoshi Baba, Patrick White, Al Zarnowski, Fit and fill analysis of a newly designed femoral stem in cementless total hip arthroplasty for patients with secondary osteoarthritis Journal of Orthopaedic Science. ,vol. 2, pp. 301- 312 ,(1997) , 10.1007/BF02488914
Yeon Soo Lee, Seung Hoon Oh, Jong Keun Seon, Eun Kyoo Song, Taek Rim Yoon, 3D femoral neck anteversion measurements based on the posterior femoral plane in ORTHODOC system. Medical & Biological Engineering & Computing. ,vol. 44, pp. 895- 906 ,(2006) , 10.1007/S11517-006-0104-7
I. Gibson, L.K. Cheung, S.P. Chow, W.L. Cheung, S.L. Beh, M. Savalani, S.H. Lee, The use of rapid prototyping to assist medical applications Rapid Prototyping Journal. ,vol. 12, pp. 53- 58 ,(2006) , 10.1108/13552540610637273