The Complex Fenestration Construction: a practical approach for modelling windows with shading devices in ESP-r

作者: Bartosz A. Lomanowski , John L. Wright

DOI: 10.1080/19401493.2011.552735

关键词:

摘要: The use of operable shading devices impacts building loads significantly. need exists for an explicit treatment window in the design energy-efficient buildings through simulation. A general framework modelling complex fenestration systems, Complex Fenestration Construction (CFC), has recently been implemented ESP-r. underlying models have developed with emphasis on computational efficiency and straightforward input requirements. capabilities are summarized, overview solar-optical thermal is given. Simulations were carried out comparing CFC ESP-r to slat-type blind EnergyPlus. results show good agreement between two simulation programs. Work ongoing expand types shade layers available CFC.

参考文章(28)
Eames P.C., Zhao, J, Wang J., , Hyde, T.J., Fang Y., Advanced Glazing Systems Renewable Energy Innovative Ideas and Building Technologies Conference. pp. 27- 30 ,(2006)
C G Granqvist, J L Wright, K G T Hollands, Glazings and Coatings Solar Energy: The State of the Art, edited by J. Gordon (James & James Science Publishers, London, England, 2001) pp. 29-107.. pp. 29- 107 ,(2001)
Joseph Andrew Clarke, Energy Simulation in Building Design ,(1985)
E.U. Finlayson, D.K. Arasteh, C. Huizenga, M.D. Rubin, M.S. Reilly, WINDOW 4.0: Documentation of calculation procedures ,(1993) , 10.2172/10112503
Bartosz Aleksander Lomanowski, Implementation of Window Shading Models into Dynamic Whole-Building Simulation Theory of Computing Systems \/ Mathematical Systems Theory. pp. 2- ,(2008)
N. A. Kotey, M. R. Collins, J. L. Wright, T. Jiang, A Simplified Method for Calculating the Effective Solar Optical Properties of a Venetian Blind Layer for Building Energy Simulation Journal of Solar Energy Engineering-transactions of The Asme. ,vol. 131, pp. 021002- ,(2009) , 10.1115/1.3090822
A. Laouadi, Thermal performance modelling of complex fenestration systems Journal of Building Performance Simulation. ,vol. 2, pp. 189- 207 ,(2009) , 10.1080/19401490903046785
E. Shewen, K. G. T. Hollands, G. D. Raithby, Heat Transfer by Natural Convection Across a Vertical Air Cavity of Large Aspect Ratio Journal of Heat Transfer-transactions of The Asme. ,vol. 118, pp. 993- 995 ,(1996) , 10.1115/1.2822603
F. Alamdari, G. P. Hammond, Improved data correlations for buoyancy-driven convection in rooms: Building Services Engineering Research and Technology. ,vol. 4, pp. 106- 112 ,(1983) , 10.1177/014362448300400304
Hidayat Shahid, David Naylor, Energy performance assessment of a window with a horizontal Venetian blind Energy and Buildings. ,vol. 37, pp. 836- 843 ,(2005) , 10.1016/J.ENBUILD.2004.11.008