Assessment of heart rate variability derived from finger-tip photoplethysmography as compared to electrocardiography

作者: N. Selvaraj , A. Jaryal , J. Santhosh , K. K. Deepak , S. Anand

DOI: 10.1080/03091900701781317

关键词:

摘要: Heart rate variability (HRV) is traditionally derived from RR interval time series of electrocardiography (ECG). Photoplethysmography (PPG) also reflects the cardiac rhythm …

参考文章(18)
J.L.A. Carvalho, A.F. Rocha, L.F. Junqueira, J.S. Neto, I. Santos, F.A.O. Nascimento, A tool for time-frequency analysis of heart rate variability international conference of the ieee engineering in medicine and biology society. ,vol. 3, pp. 2574- 2577 ,(2003) , 10.1109/IEMBS.2003.1280441
Anders Johansson, C Ahlstrom, T Lanne, Per Ask, None, Pulse wave transit time for monitoring respiration rate. Medical & Biological Engineering & Computing. ,vol. 44, pp. 471- 478 ,(2006) , 10.1007/S11517-006-0064-Y
A. Porta, C. Gasperi, G. Nollo, D. Lucini, P. Pizzinelli, R. Antolini, M. Pagani, Global versus local linear beat-to-beat analysis of the relationship between arterial pressure and pulse transit time during dynamic exercise Medical & Biological Engineering & Computing. ,vol. 44, pp. 331- 337 ,(2006) , 10.1007/S11517-006-0042-4
B. Khanoka, Y. Slovik, D. Landau, M. Nitzan, Sympathetically induced spontaneous fluctuations of the photoplethysmographic signal. Medical & Biological Engineering & Computing. ,vol. 42, pp. 80- 85 ,(2004) , 10.1007/BF02351014
Meir Nitzan, Anatoly Babchenko, Boris Khanokh, David Landau, The variability of the photoplethysmographic signal - a potential method for the evaluation of the autonomic nervous system Physiological Measurement. ,vol. 19, pp. 93- 102 ,(1998) , 10.1088/0967-3334/19/1/008
Jarosław Piskorski, Przemysław Guzik, Filtering Poincaré plots computational methods in science and technology. ,vol. 11, pp. 39- 48 ,(2005) , 10.12921/CMST.2005.11.01.39-48
Gohichi Tanaka, Yukihiro Sawada, Examination of normalized pulse volume-blood volume relationship: toward a more valid estimation of the finger sympathetic tone. International Journal of Psychophysiology. ,vol. 48, pp. 293- 306 ,(2003) , 10.1016/S0167-8760(03)00056-4
John Allen, Photoplethysmography and its application in clinical physiological measurement Physiological Measurement. ,vol. 28, pp. R1- R39 ,(2007) , 10.1088/0967-3334/28/3/R01
Michael J Drinnan, John Allen, Alan Murray, Relation between heart rate and pulse transit time during paced respiration Physiological Measurement. ,vol. 22, pp. 425- 432 ,(2001) , 10.1088/0967-3334/22/3/301
Nicholas D. Giardino, Paul M. Lehrer, Robert Edelberg, Comparison of finger plethysmograph to ECG in the measurement of heart rate variability Psychophysiology. ,vol. 39, pp. 246- 253 ,(2002) , 10.1111/1469-8986.3920246