Swept Langmuir probe investigation of a time varying DC discharge

作者: S. Hussain , F. Deeba , S. Ahmad , A. Qayyum , M. Usman Naseer

DOI: 10.1007/S42452-020-04019-9

关键词:

摘要: The paper reports on the development and application of a swept Langmuir probe to characterize plasma between two disc-like electrodes. A battery was added circuit offset against cathode fall voltage, make sweep voltage effective at tip. This arrangement allowed collection electron ion parts current subsequent construction time-resolved current–voltage IP(V) characteristics with time resolution about one millisecond. collected in lower region discharge waveform where it surmounted whereas continuously due an accelerating field for ions. results highlighted how limits handle problem series circuit. In addition single-probe, triple-probe used simultaneously compare validate results.

参考文章(27)
Enling Tang, Shenghai Xiang, Minghai Yang, Lexin Li, Sweep Langmuir Probe and Triple Probe Diagnostics for Transient Plasma Produced by Hypervelocity Impact Plasma Science & Technology. ,vol. 14, pp. 747- 753 ,(2012) , 10.1088/1009-0630/14/8/12
Robert B. Lobbia, Alec D. Gallimore, High-speed dual Langmuir probe Review of Scientific Instruments. ,vol. 81, pp. 073503- ,(2010) , 10.1063/1.3455201
D. L. Rudakov, J. A. Boedo, R. A. Moyer, P. C. Stangeby, A. McLean, J. G. Watkins, Effect of electron temperature fluctuations on slowly swept Langmuir probe measurements Review of Scientific Instruments. ,vol. 75, pp. 4334- 4337 ,(2004) , 10.1063/1.1789623
A. Qayyum, N. Ahmad, S. Ahmad, Farah Deeba, Rafaqat Ali, S. Hussain, Time-resolved measurement of plasma parameters by means of triple probe. Review of Scientific Instruments. ,vol. 84, pp. 123502- ,(2013) , 10.1063/1.4838658
J. L. Jauberteau, I. Jauberteau, Determination of the electron density in plasma by means of a floating double probe. Review of Scientific Instruments. ,vol. 79, pp. 033505- ,(2008) , 10.1063/1.2900579
M Mitov, A Bankova, M Dimitrova, P Ivanova, K Tutulkov, N Djermanova, R Dejarnac, J Stöckel, Tsv K Popov, Electronic system for Langmuir probe measurements Journal of Physics: Conference Series. ,vol. 356, pp. 012008- ,(2012) , 10.1088/1742-6596/356/1/012008
Robert L. Merlino, Understanding Langmuir probe current-voltage characteristics American Journal of Physics. ,vol. 75, pp. 1078- 1085 ,(2007) , 10.1119/1.2772282
G. Chiodini, C. Riccardi, M. Fontanesi, A 400 kHz, fast-sweep Langmuir probe for measuring plasma fluctuations Review of Scientific Instruments. ,vol. 70, pp. 2681- 2688 ,(1999) , 10.1063/1.1149828
C. Riccardi, G. Longoni, G. Chiodini, M. Fontanesi, Comparison between fast-sweep Langmuir probe and triple probe for fluctuations measurements Review of Scientific Instruments. ,vol. 72, pp. 461- 464 ,(2001) , 10.1063/1.1310578