Performance Test of an LSO-APD Detector in a 7-T MRI Scanner for Simultaneous PET/MRI

作者: Martin S Judenhofer , Martin S Judenhofer , Simon R Cherry , Ciprian Catana , Jeffrey H Walton

DOI:

关键词:

摘要: … Figure 1A shows an example of an in vivo cell-trafficking study; 10 6 tumor antigen (Tag)–specific Th1 cells were labeled in vitro with 64 Cu-pyruvaldehyde-bis(N4-…

参考文章(30)
Beyer T, Townsend Dw, Blodgett Tm, Dual-modality PET/CT tomography for clinical oncology. The quarterly journal of nuclear medicine : official publication of the Italian Association of Nuclear Medicine. ,vol. 46, pp. 24- 34 ,(2002)
Sibylle I. Ziegler, Bernd J. Pichler, Guido Boening, Magdalena Rafecas, Wendelin Pimpl, Eckart Lorenz, Norbert Schmitz, Markus Schwaiger, A prototype high-resolution animal positron tomograph with avalanche photodiode arrays and LSO crystals. European Journal of Nuclear Medicine and Molecular Imaging. ,vol. 28, pp. 136- 143 ,(2001) , 10.1007/S002590000438
Ralph Weissleder, Scaling down imaging: molecular mapping of cancer in mice Nature Reviews Cancer. ,vol. 2, pp. 11- 18 ,(2002) , 10.1038/NRC701
B J Pichler, B K Swann, J Rochelle, R E Nutt, S R Cherry, S B Siegel, Lutetium oxyorthosilicate block detector readout by avalanche photodiode arrays for high resolution animal PET Physics in Medicine and Biology. ,vol. 49, pp. 4305- 4319 ,(2004) , 10.1088/0031-9155/49/18/008
Jens Werner, Jan Schmidt, Andrew L. Warshaw, Martha M. Gebhard, Christian Herfarth, Ernst Klar, The relative safety of MRI contrast agent in acute necrotizing pancreatitis Annals of Surgery. ,vol. 227, pp. 105- 111 ,(1998) , 10.1097/00000658-199801000-00015
Martin S Judenhofer, Bernd J Pichler, Simon R Cherry, Evaluation of high performance data acquisition boards for simultaneous sampling of fast signals from PET detectors Physics in Medicine and Biology. ,vol. 50, pp. 29- 44 ,(2005) , 10.1088/0031-9155/50/1/003
Xiao-Dong Liu, Shu-Mei Ma, Shu-Zheng Liu, Effects of 0.075 Gy x-ray irradiation on the expression of IL-10 and IL-12 in mice. Physics in Medicine and Biology. ,vol. 48, pp. 2041- 2049 ,(2003) , 10.1088/0031-9155/48/13/315
Peter J. Ell, Gustav K. von Schulthess, PET/CT: a new road map. European Journal of Nuclear Medicine and Molecular Imaging. ,vol. 29, pp. 719- 720 ,(2002) , 10.1007/S00259-002-0844-Z
P A Dokhale, R W Silverman, K S Shah, R Grazioso, R Farrell, J Glodo, M A McClish, G Entine, V-H Tran, S R Cherry, Performance measurements of a depth-encoding PET detector module based on position-sensitive avalanche photodiode read-out. Physics in Medicine and Biology. ,vol. 49, pp. 4293- 4304 ,(2004) , 10.1088/0031-9155/49/18/007
Yolanda D Mahnke, Volker Schirrmacher, A novel tumour model system for the study of long-term protective immunity and immune T cell memory Cellular Immunology. ,vol. 221, pp. 89- 99 ,(2003) , 10.1016/S0008-8749(03)00062-5