Three-dimensional CFD modeling and simulation on the performance of steam ejector heat pump for dryer section of the paper machine

作者: Yuejin Yuan , Libin Tan , Yingying Xu , Yueding Yuan

DOI: 10.1016/J.VACUUM.2015.09.016

关键词:

摘要: Abstract A three-dimensional model of the steam ejector heat pump for dryer section paper machine was developed by applying Computational Fluid Dynamics (CFD) technique, which provided pressure and velocity distributions fluid flow in pump. The results indicated that field has an incomplete axially symmetrical distribution. entrainment ratio initially increases rapidly with increase ejected inlet then decreases after exceeds one certain value. There exists a critical value mixed under given operating conditions. optimal diameter constant area mixing to nozzle throat is about 3.4 length L/D m 6. An divergence angle diffuser observed different length. optimized position condition where maximum observed. CFD technique found be efficient alternative predict performance conclusions research can provide beneficial reference structural optimization design ejector.

参考文章(51)
Krzysztof Banasiak, Armin Hafner, Ekaterini E. Kriezi, Kenneth B. Madsen, Michael Birkelund, Kristian Fredslund, Rickard Olsson, Development and performance mapping of a multi-ejector expansion work recovery pack for R744 vapour compression units. International Journal of Refrigeration-revue Internationale Du Froid. ,vol. 57, pp. 265- 276 ,(2015) , 10.1016/J.IJREFRIG.2015.05.016
Adriano Milazzo, Andrea Rocchetti, Modelling of ejector chillers with steam and other working fluids International Journal of Refrigeration-revue Internationale Du Froid. ,vol. 57, pp. 277- 287 ,(2015) , 10.1016/J.IJREFRIG.2015.05.015
Bogdan M. Diaconu, Szabolcs Varga, Armando C. Oliveira, Numerical simulation of a solar-assisted ejector air conditioning system with cold storage Energy. ,vol. 36, pp. 1280- 1291 ,(2011) , 10.1016/J.ENERGY.2010.11.015
M. Nakagawa, A.R. Marasigan, T. Matsukawa, A. Kurashina, Experimental investigation on the effect of mixing length on the performance of two-phase ejector for CO2 refrigeration cycle with and without heat exchanger International Journal of Refrigeration-revue Internationale Du Froid. ,vol. 34, pp. 1604- 1613 ,(2011) , 10.1016/J.IJREFRIG.2010.07.021
Yosr Allouche, Chiheb Bouden, Szabolcs Varga, A CFD analysis of the flow structure inside a steam ejector to identify the suitable experimental operating conditions for a solar-driven refrigeration system International Journal of Refrigeration-revue Internationale Du Froid. ,vol. 39, pp. 186- 195 ,(2014) , 10.1016/J.IJREFRIG.2013.07.027
Sepehr Sanaye, Behzad Niroomand, Vertical ground coupled steam ejector heat pump; thermal-economic modeling and optimization International Journal of Refrigeration-revue Internationale Du Froid. ,vol. 34, pp. 1562- 1576 ,(2011) , 10.1016/J.IJREFRIG.2010.03.004
Lin Zhu, Jianlin Yu, Mengliu Zhou, Xiao Wang, Performance analysis of a novel dual-nozzle ejector enhanced cycle for solar assisted air-source heat pump systems Renewable Energy. ,vol. 63, pp. 735- 740 ,(2014) , 10.1016/J.RENENE.2013.10.030
Byung Hoon Park, Ji Hyung Lee, Woongsup Yoon, Studies on the starting transient of a straight cylindrical supersonic exhaust diffuser: Effects of diffuser length and pre-evacuation state International Journal of Heat and Fluid Flow. ,vol. 29, pp. 1369- 1379 ,(2008) , 10.1016/J.IJHEATFLUIDFLOW.2008.04.006
Jia Yan, Wenjian Cai, Yanzhong Li, Geometry parameters effect for air-cooled ejector cooling systems with R134a refrigerant Renewable Energy. ,vol. 46, pp. 155- 163 ,(2012) , 10.1016/J.RENENE.2012.03.031