A New Diagnostic Technique to Detect Early Migration of Joint Prostheses

作者: Muhammad Moid Khalid Khan , Subodh C Deshmukh , Kanthan Theivendran , Laura J Leslie , Sarah Junaid

DOI: 10.1109/ACCESS.2021.3049170

关键词:

摘要: Migration of an implanted prosthesis due to aseptic loosening is difficult detect without regular imaging. In this paper, a low-cost, non-radiographic, robust diagnostic technique presented, which can the migration humeral component elbow prosthesis. The system consists single magnet sensor configuration and data are based on variation in magnetic field. was enclosed titanium alloy embedded at reference point bone ultra-high molecular weight polyethylene (UHMWPE). A layer cement then placed between sensor. An algorithm linked with Savitzky- Golay (SG) filter developed that could decouple, convert, field signal provide both linear angular displacement. also designed eliminate cross talk non-linearity effect magnet. highest resolution achieved 0.3 mm detectable range 4 x/y axis 8-20 z-axis (along canal). rotational 0.5 3.0 degrees axis. repeatability calibrated analysed showed standard deviation 0.05 over 150 cycles. dependent upon operating conditions positioning. There no interference from alloy, nor UHMWPE. This offers alternative non-radiographic option for measuring prostheses.

参考文章(33)
Chidambaram Natrajan Balasubramanian Harisankar, Bhagwant Rai Mittal, Anish Bhattacharya, Madan Parmar, Baljinder Singh, Aseptic Loosening of Elbow Prostheses Diagnosed on F-18 FDG PET/CT Clinical Nuclear Medicine. ,vol. 35, pp. 886- 887 ,(2010) , 10.1097/RLU.0B013E3181F49E16
Heng-Sheng Hsiao, Li-Qing Chen, Cheng-Kuo Sung, Jen-Yuan (James) Chang, Characteristics of magnetic sensor with assembly errors in a rotary recording system Microsystem Technologies-micro-and Nanosystems-information Storage and Processing Systems. ,vol. 26, pp. 89- 94 ,(2020) , 10.1007/S00542-019-04449-5
Sosa, J.M Camacho, Alternative method to calculate the magnetic field of permanent magnets with azimuthal symmetry Revista Mexicana De Fisica E. ,vol. 59, pp. 8- 17 ,(2013)
Syed Mahfuzul Aziz, Milos Grcic, Tharshan Vaithianathan, A Real-Time Tracking System for an Endoscopic Capsule using Multiple Magnetic Sensors ssst. pp. 201- 218 ,(2008) , 10.1007/978-3-540-79590-2_14
Eerik T Skyttä, Antti Eskelinen, Pekka Paavolainen, Mikko Ikävalko, Ville Remes, Total elbow arthroplasty in rheumatoid arthritis: A population-based study from the Finnish Arthroplasty Register Acta Orthopaedica. ,vol. 80, pp. 472- 477 ,(2009) , 10.3109/17453670903110642
G. Bergmann, F. Graichen, A. Rohlmann, Hip joint loading during walking and running, measured in two patients Journal of Biomechanics. ,vol. 26, pp. 969- 990 ,(1993) , 10.1016/0021-9290(93)90058-M
A. Arami, M. Simoncini, O. Atasoy, S. Ali, W. Hasenkamp, A. Bertsch, E. Meurville, S. Tanner, P. Renaud, C. Dehollain, P. Farine, B. M. Jolles, K. Aminian, P. Ryser, Instrumented Knee Prosthesis for Force and Kinematics Measurements IEEE Transactions on Automation Science and Engineering. ,vol. 10, pp. 615- 624 ,(2013) , 10.1109/TASE.2012.2226030
Steven H. Goldberg, Robert M. Urban, Joshua J. Jacobs, Graham JW King, Shawn W. OʼDriscoll, Mark S. Cohen, Modes of Wear After Semiconstrained Total Elbow Arthroplasty The Journal of Bone and Joint Surgery-American Volume. ,vol. 90, pp. 609- 619 ,(2008) , 10.2106/JBJS.F.01286
C. Schott, F. Burger, H. Blanchard, L. Chiesi, Modern integrated silicon Hall sensors Sensor Review. ,vol. 18, pp. 252- 257 ,(1998) , 10.1108/02602289810240628
Arash Arami, Jenifer Miehlbradt, Kamiar Aminian, Accurate Internal-External Rotation Measurement in Total Knee Prostheses: a magnetic solution Journal of Biomechanics. ,vol. 45, pp. 2023- 2027 ,(2012) , 10.1016/J.JBIOMECH.2012.05.023