A highly selective and sensitive fluorescence assay for determination of copper(ii) and cobalt(ii) ions in environmental water and toner samples

作者: Chia-Yi Tsai , Yang-Wei Lin

DOI: 10.1039/C2AN36290B

关键词:

摘要: In this study, a highly selective and sensitive fluorescence assay has been proposed for the determination of copper(II) cobalt(II) ions in environmental water toner samples. presence hydrogen peroxide, reacted with new reagent Amplex® UltraRed (AUR), forming product only at pH 7.0, while AUR formed 9.0. The signal obtained was linear respect to concentration over range 1.6–12.0 μM (R2 = 0.988) 45.0 nM 1.0 0.992). limits detection (at signal-to-noise ratio 3) were 0.17 14.0 nM, respectively. Our present approach is simpler, faster, more cost-effective than other techniques samples that

参考文章(38)
Yanmei Lu, Zhibin Ou, Wei Hu, Xueyi Le, (2-(2'-吡啶)苯并咪唑)( L -丙氨酸根)铜(II)配合物结构、抗菌活性及DNA断裂作用 Acta Chimica Sinica. ,vol. 70, pp. 973- 979 ,(2012) , 10.6023/A1110252
Eshan Patel, Christine Lynch, Victoria Ruff, Mindy Reynolds, Co-exposure to nickel and cobalt chloride enhances cytotoxicity and oxidative stress in human lung epithelial cells. Toxicology and Applied Pharmacology. ,vol. 258, pp. 367- 375 ,(2012) , 10.1016/J.TAAP.2011.11.019
Na Shao, Jian Yu Jin, Hao Wang, Ying Zhang, Rong Hua Yang, Wing Hong Chan, Tunable photochromism of spirobenzopyran via selective metal ion coordination: an efficient visual and ratioing fluorescent probe for divalent copper ion. Analytical Chemistry. ,vol. 80, pp. 3466- 3475 ,(2008) , 10.1021/AC800072Y
Weiying Lin, Lingliang Long, Bingbing Chen, Wen Tan, Wensha Gao, Fluorescence turn-on detection of Cu2+ in water samples and living cells based on the unprecedented copper-mediated dihydrorosamine oxidation reaction Chemical Communications. ,vol. 46, pp. 1311- 1313 ,(2010) , 10.1039/B919531A
T. Hirayama, G. C. Van de Bittner, L. W. Gray, S. Lutsenko, C. J. Chang, Near-infrared fluorescent sensor for in vivo copper imaging in a murine Wilson disease model Proceedings of the National Academy of Sciences of the United States of America. ,vol. 109, pp. 2228- 2233 ,(2012) , 10.1073/PNAS.1113729109
Afshin Rajabi Khorrami, Ali Reza Fakhari, Mojtaba Shamsipur, Hossein Naeimi, Pre-concentration of ultra trace amounts of copper, zinc, cobalt and nickel in environmental water samples using modified C18 extraction disks and determination by inductively coupled plasma-optical emission spectrometry. International Journal of Environmental Analytical Chemistry. ,vol. 89, pp. 319- 329 ,(2009) , 10.1080/03067310802549953
Juewen Liu, Yi Lu, None, A DNAzyme catalytic beacon sensor for paramagnetic Cu2+ ions in aqueous solution with high sensitivity and selectivity. Journal of the American Chemical Society. ,vol. 129, pp. 9838- 9839 ,(2007) , 10.1021/JA0717358