Experiment investigation of reverse cycle defrosting methods on air source heat pump with TXV as the throttle regulator

作者: Yanjun Ding , Guoyuan Ma , Qinhu Chai , Yi Jiang

DOI: 10.1016/J.IJREFRIG.2004.01.008

关键词:

摘要: Reverse-cycle defrosting technique is one of the simplest and most widely used methods for air source heat pumps (ASHP). However, there are still some problems if thermal expansive valve (TXV) as throttle regulator in unit: process might last so long that users would feel uncomfortable due to fluctuation indoor temperature: system cannot resume heating mode smoothly after process, often breaks down triggering low-pressure switch. In this paper authors proposed these two can be greatly relieved a by-pass solenoid which TXV mode, best performance addressed energized during whole process.

参考文章(3)
P.P. Votsis, S.A. Tassou, D.R. Wilson, C.J. Marquand, Investigation of the performance of a heat pump under frosting and defrosting conditions Heat Recovery Systems and Chp. ,vol. 9, pp. 399- 406 ,(1989) , 10.1016/0890-4332(89)90142-7
Dennis L O'Neal, Kurt Peterson, N.K Anand, Effect of short-tube orifice size on the performance of an air source heat pump during the reverse-cycle defrost International Journal of Refrigeration-revue Internationale Du Froid. ,vol. 14, pp. 52- 57 ,(1991) , 10.1016/0140-7007(91)90022-9
Ma Guoyuan, Chai Qinhu, Jiang Yi, Experimental investigation of air-source heat pump for cold regions International Journal of Refrigeration-revue Internationale Du Froid. ,vol. 26, pp. 12- 18 ,(2003) , 10.1016/S0140-7007(02)00083-X