Impairment of carotid artery blood flow by supraglottic airway use in a swine model of cardiac arrest

作者: Nicolas Segal , Demetris Yannopoulos , Brian D. Mahoney , Ralph J. Frascone , Timothy Matsuura

DOI: 10.1016/J.RESUSCITATION.2012.03.025

关键词:

摘要: a b s t r c Objective: Supraglottic airway devices (SGDs) are often used as an alternative to endotracheal tube (ETT) during cardiopulmonary resuscitation (CPR). SGDs can be inserted 'blindly' and rapidly, without stopping compressions. These utilize pressurized balloons direct air the trachea prevent esoph- agus insufflation. We hypothesize that use of SGD will compress carotid artery decrease blood flow (CBF) CPR in pigs. Methods: Ventricular fibrillation (VF) was induced 9 female pigs (32 ± 1 kg) followed by 4 min then performed continuously for 3-6-min intervals. During each interval, ETT first 3 min, (King LTS-D TM

参考文章(18)
C. H. Charlesworth, P. R. Nandi, J. F. Nunn, S. J. Taylor, Radiological study of the Laryngeal Mask. European Journal of Anaesthesiology - Supplement. ,vol. 4, pp. 33- 39 ,(1991)
J. Bracken Burns, Richard Branson, Stephen L. Barnes, Betty J. Tsuei, Emergency Airway Placement by EMS Providers: Comparison between the King LT Supralaryngeal Airway and Endotracheal Intubation Prehospital and Disaster Medicine. ,vol. 25, pp. 92- 95 ,(2010) , 10.1017/S1049023X00007743
Jerry P Nolan, Jasmeet Soar, Airway techniques and ventilation strategies. Current Opinion in Critical Care. ,vol. 14, pp. 279- 286 ,(2008) , 10.1097/MCC.0B013E3282F85BC8
Christopher S. Russi, Lonny Miller, Michael J. Hartley, A comparison of the King-LT to endotracheal intubation and Combitube in a simulated difficult airway. Prehospital Emergency Care. ,vol. 12, pp. 35- 41 ,(2008) , 10.1080/10903120701710488
Howard G. Wakeling, Patrick J. Butler, Peter J. C. Baxter, The laryngeal mask airway: a comparison between two insertion techniques Anesthesia & Analgesia. ,vol. 85, pp. 687- 690 ,(1997) , 10.1097/00000539-199709000-00037
Sally-Ann Colbert, Deirdre M. Ohanlon, Fidelma Flanagan, Rory Page, Denis C. Moriarty, The laryngeal mask airway reduces blood flow in the common carotid artery bulb. Canadian Journal of Anaesthesia-journal Canadien D Anesthesie. ,vol. 45, pp. 23- 27 ,(1998) , 10.1007/BF03011987
N. Nandwani, M. C. Fairfield, K. Krarup, J. Thompson, The effect of laryngeal mask airway insertion on the position of the internal jugular vein Anaesthesia. ,vol. 52, pp. 77- 79 ,(1997) , 10.1111/J.1365-2044.1997.012-AZ012.X
J. Brimacombe, C. Keller, Comparison of the flexible and standard laryngeal mask airways. Canadian Journal of Anaesthesia-journal Canadien D Anesthesie. ,vol. 46, pp. 558- 563 ,(1999) , 10.1007/BF03013546
Demetris Yannopoulos, Vinay M. Nadkarni, Scott H. McKnite, Anu Rao, Kurt Kruger, Anja Metzger, David G. Benditt, Keith G. Lurie, Intrathoracic Pressure Regulator During Continuous-Chest-Compression Advanced Cardiac Resuscitation Improves Vital Organ Perfusion Pressures in a Porcine Model of Cardiac Arrest Circulation. ,vol. 112, pp. 803- 811 ,(2005) , 10.1161/CIRCULATIONAHA.105.541508