A ratiometric fluorescence chemosenser for Hg2+ based on Primuline and layered double hydroxide ultrafilms

作者: Hao Chen , Xiaolan Ji , Shitong Zhang , Wenying Shi , Min Wei

DOI: 10.1016/J.SNB.2012.12.075

关键词:

摘要: Abstract The fabrication of fluorescence indicator/layered double hydroxide (LDH) ultrathin films (UTFs) by alternate assembly Primuline and Mg-Al LDH nanosheets using the layer-by-layer (LBL) deposition technique has been reported, their application as a raitometric chemosensor for Hg 2+ is demonstrated. Primuline/LDH UTFs show stepwise regular growth upon increasing cycles proved UV–vis absorption emission spectroscopy, periodical layered structure perpendicular to substrates with thickness 2.41–2.48 nm per bilayer observed X-ray diffraction scanning electron microscopy. Furthermore, linear correlation between intensity ratio ( I 422 / 377 ) UTF concentration obtained  = 2.63–0.01 c nM, r 2  = 0.99), detection limit 0.13 pM. results have also exhibited that ratiometric possess good repeatability, high stability (light, storage mechanics) well excellent selectivity. In addition, mechanism measurement–regeneration cycle indicates enters/departs from giving rise reversible change in chemical composition, surface morphology anisotropy UTF. Therefore, this work provides new opportunities chromophore/LDH chemosensors.

参考文章(32)
Valderi L. Dressler, Fabiane Goldschmidt Antes, Clarissa Marques Moreira, Dirce Pozebon, Fabio Andrei Duarte, As, Hg, I, Sb, Se and Sn speciation in body fluids and biological tissues using hyphenated-ICP-MS techniques: A review International Journal of Mass Spectrometry. ,vol. 307, pp. 149- 162 ,(2011) , 10.1016/J.IJMS.2011.01.026
Gareth R. Williams, Dermot O'Hare, Towards understanding, control and application of layered double hydroxide chemistry Journal of Materials Chemistry. ,vol. 16, pp. 3065- 3074 ,(2006) , 10.1039/B604895A
Tiberiu Frentiu, Alin I. Mihaltan, Michaela Ponta, Eugen Darvasi, Maria Frentiu, Emil Cordos, Mercury determination in non- and biodegradable materials by cold vapor capacitively coupled plasma microtorch atomic emission spectrometry. Journal of Hazardous Materials. ,vol. 193, pp. 65- 69 ,(2011) , 10.1016/J.JHAZMAT.2011.07.031
Ranko P. Bontchev, Shirley Liu, James L. Krumhansl, James Voigt, Tina M. Nenoff, Synthesis, Characterization, and Ion Exchange Properties of Hydrotalcite Mg6Al2(OH)16(A)x(A‘)2-x·4H2O (A, A‘ = Cl-, Br-, I-, and NO3-, 2 ≥ x ≥ 0) Derivatives Chemistry of Materials. ,vol. 15, pp. 3669- 3675 ,(2003) , 10.1021/CM034231R
Huan-Huan Wang, Lin Xue, Cai-Lan Yu, Yuan-Yu Qian, Hua Jiang, Rhodamine-based fluorescent sensor for mercury in buffer solution and living cells Dyes and Pigments. ,vol. 91, pp. 350- 355 ,(2011) , 10.1016/J.DYEPIG.2011.04.007
Sultan I Amer, Simplified removal of chelated metals Metal Finishing. ,vol. 102, pp. 36- 40 ,(2004) , 10.1016/S0026-0576(04)90237-1
Qiang Wang, Dermot O’Hare, Recent advances in the synthesis and application of layered double hydroxide (LDH) nanosheets. Chemical Reviews. ,vol. 112, pp. 4124- 4155 ,(2012) , 10.1021/CR200434V
Fang-Jun Huo, Jing-Jing Zhang, Yu-Tao Yang, Jian-Bin Chao, Cai-Xia Yin, Yong-Bin Zhang, Ting-Gui Chen, A fluorescein-based highly specific colorimetric and fluorescent probe for hypochlorites in aqueous solution and its application in tap water Sensors and Actuators B-chemical. ,vol. 166, pp. 44- 49 ,(2012) , 10.1016/J.SNB.2011.11.081