An eddy-current-shielded room with a partially closed entrance

作者: G. Stroink , C. Purcell , F. Brauer , B. Blackford

DOI: 10.1007/BF02455923

关键词:

摘要: We show that substantial improvements can be obtained in the shielding properties of an eddy-current-shielded room by covering doorway with conductive plates. Results suggest it is unnecessary to install a door and worthwhile small part permanently.

参考文章(5)
G. Stroink, B. Blackford, B. Brown, M. Horacek, Aluminum shielded room for biomagnetic measurements Review of Scientific Instruments. ,vol. 52, pp. 463- 468 ,(1981) , 10.1063/1.1136612
P Heinonen, M Tuomola, J Lekkala, J Malmivuo, Properties of a thick-walled conducting enclosure in low-frequency magnetic shielding Journal of Physics E: Scientific Instruments. ,vol. 13, pp. 569- 570 ,(1980) , 10.1088/0022-3735/13/5/024
James E. Zimmerman, SQUID instruments and shielding for low‐level magnetic measurements Journal of Applied Physics. ,vol. 48, pp. 702- 710 ,(1977) , 10.1063/1.323659
C. Bercy, D. Duret, P. Karp, D. Teszner, Installation Of A Biomagnetic Measurement Facility In A Hospital Environment De Gruyter. pp. 95- 106 ,(1981) , 10.1515/9783110863529-008